Reports 1-1 of 1 Clear search Modify search
Environmental Monitoring (Environmental Monitoring)
fiori, paoletti, tringali - 16:23 Thursday 26 March 2020 (48816) Print this report
Acoustic injections CEB hall

This morning we injected some acoustic noise with this loudspeaker setup: Figure 1

The log file with details and gps times is attached.

We injected:

  • colored noise in some bands: 10 to 2kHz, then more narrow slices to better cover the low frequency region from approximately 25 to 300Hz.
  • then we injected a set of 10 equi-spaced  lines from 21 to 101
  • finally we injected a pair of lines: 180. and 180.01 to greating a beating sound around 180Hz (180.05) with amplitude modulation of 50s 

W noticed some interesting bump-like structures rising in Hrec:

  • a bump 40-60Hz: Figure 2
  • a bump around 160 Hz: Figure 3
  • some structures around 290Hz, besides the known DET structures around 420Hz: Figure 4

A more deep investigation will follow.

Images attached to this report
Non-image files attached to this report
Comments to this report:
Paoletti, Fiori, Tringali - 19:15 Friday 27 March 2020 (48835) Print this report

We took a look at some of the accelerometers that we have in the CEB during the acoustic injection done with white and band-passed shaped noise.

The broadband noise injection  (10 to 1990 Hz) from 10:28:00 to 10:34:00 UTC is mainly visible in:

ENV_IB_CT_ACC_X
ENV_SIB2_ACC_Z

ENV_PR_ACC_Z
ENV_PR_LINK_ACC_Z

ENV_SPRBLINK_ACC_Z

ENV_WI_ACC_X
ENV_WI_CT_ACC_Z

ENV_NI_ACC_X
ENV_NI_CT_EXT_ACC_Z
ENV_NI_LINK_ACC_Z

ENV_SR_ACC_Z
ENV_SR_EAST_ACC_Z

ENV_SQZ_PIPE_ACC_Y

ENV_DT_ACC_Z
ENV_DT_CT_ACC_Z

(but the effect of the acoustic noise ismore or less visible in all *ACC* sensors)

It is worth noting that some of these ENV_ACC sensors are dominated by mains harmonics; these are:

ENV_TCS_CO2_NI_ACC_Y
ENV_TCS_CO2_WI_ACC_Y
ENV_SQZ_PIPE_ACC_Y
ENV_SQZ_ACC_Y

We see some Hrec structures growing from 400 to 500Hz, characteristics of DET diffused light, and we also see noise between 160 and 170 Hz and a "volcano" structure around 50Hz

The detail of the band-shaped noise injection (time always UTC) is given below:

Band-limited noise (0-50Hz) 10:41:00 to 10:49:00 level 5e-3
"Volcano" 40-60 Hz growing in Hrec, but no coherence in ACC sensors

Band-limited noise (0-120Hz) 10:35:00 to 10:40:00 level 1e-3
level too low, not really visible in Hrec

Band-limited noise (100-200Hz) 10:51:00 to 10:57:00 level 2e-3
bump 160-170 Hz growing in Hrec, mainly visible in the accelerometers ENV_NI_* and in ENV_SQZ_PIPE_ACC_Y plus ENV_DT_ACC_Z ; some coherence in ACC sensors, but only for some sharp lines within the bump, around 166Hz; not for the whole bump

Band-limited noise (200-300Hz) 10:59:00 to 11:09:00 level 2e-3
some thin lines that grow in Hrec at 273Hz, 282Hz, from 290 to 300Hz, 326Hz, 343Hz (in addition to the usual DET scattered light bumps from 400 to 500Hz, due to the harmonics of the sound generated by the speakers)

Due to the global spread of this noise within the CEB (and also due to the bad sound insulation of the internal walls), it is difficult to find a clear witness; some frequencies seem more prominent in some accelerometers, others in other sensors.

Images attached to this comment
Tringali, Fiori, Paoletti - 19:54 Saturday 28 March 2020 (48842) Print this report

We report the coherence between Hrec and the following ENV_MIC in the central building during the acoustic injections performed on March 26:

ENV_CEB_MIC
ENV_EDB_MIC
ENV_EIB_MIC
ENV_LB_MIC
ENV_SQZ_MIC
ENV_TCS_CO2_NI_MIC,  ENV_TCS_CO2_WI_MIC

The following coherence times refer to those reported by Federico in #48835:

Fig1 - Band-limited noise (0-50) Hz 10:41:00 to 10:49:00 level 5e-3
@(40-60) Hz growing "Volcano" structure in Hrec
@44 Hz coherence ~0.10 with ENV_TCS_CO2_WI_MIC

Fig2 - Band-limited noise (0-120) Hz 10:35:00 to 10:40:00 level 1e-3  
(40-50) Hz growing "Volcano" structure in Hrec

Fig3 - Band-limited noise (100-200) Hz 10:51:00 to 10:57:00 level 2e-3
@(160 -170) Hz  growing bump in Hrec
@166.5 Hz coherence ~0.24 with  ENV_SQZ_MIC, ENV_TCS_CO2_NI_MIC  and coherence ~0.30 with ENV_CEB_MIC,

Fig4 - Band-limited noise (200-300) Hz 10:59:00 to 11:09:00 level 2e-3
@(200 -400) Hz some lines arise in Hrec
coherence ~0.20- 0.40 with ENV_MIC_*

Images attached to this comment
Search Help
×

Warning

Error

The present report has been modified outside this window. Please check for its integrity in the main page.

Refreshing this page will move this report into drafts.

×