cjacquet - 19:18 Monday 22 December 2025 (68423) Print this report
Scans during the thermal transient fo the NE and WE RH

The aim of this shift is to measure the thermal transient of the NE and WE Ring heater. Previous measurements made during the commissioning of O4 showed a discrepancy between the RH calibration estimated from simulation and the observation [VIR-0739A-23]. Also, previous measurements made during the commissioning break between O4b and O4c showed that the astigmatism has a higher amplitude when the ring heater of the NE mirror was ON [VIR-0562A-25] (no measurement for the West arm has been made due to the change of the WE mirror). The aim of the scans presented here is to redo those measurements. This time, the new results obtained from the thermal transient of the cryotrap [68417] will be taken into account in the derivation of the calibration.

Scans started at 8:49 UTC with the ring heater off for around one hour before the start of the transient. The RHs of the West end and North end mirrors have been turned ON at 10:10UTC and 10:11UTC respectively [68421]. Below is the list of scans done during the shift with their starting and end dates. Between each series, the arms are relocked on IR and green.

UTC time-----------Action                                                          

8:49-9:21 15 iterations of scan using CARM_SET_scan_FSR(numiteration = 15, f_FSR=110000,timescan = 60.)

9:23-9:55 15 iterations of scan using CARM_SET_scan_FSR(numiteration = 15, f_FSR=110000,timescan = 60.)

9:57-10:29 15 iterations of scan using CARM_SET_scan_FSR(numiteration = 15, f_FSR=110000,timescan = 60.)

10:32-11:04 15 iterations of scan using CARM_SET_scan_FSR(numiteration = 15, f_FSR=110000,timescan = 60.)

11:07-11:38 15 iterations of scan using CARM_SET_scan_FSR(numiteration = 15, f_FSR=110000,timescan = 60.)

11:41-12:12 15 iterations of scan using CARM_SET_scan_FSR(numiteration = 15, f_FSR=110000,timescan = 60.)

12:15-12:47 15 iterations of scan using CARM_SET_scan_FSR(numiteration = 15, f_FSR=110000,timescan = 60.)

12:55-13:27 15 iterations of scan using CARM_SET_scan_FSR(numiteration = 15, f_FSR=110000,timescan = 60.)

13:30-14:02 15 iterations of scan using CARM_SET_scan_FSR(numiteration = 15, f_FSR=110000,timescan = 60.)

14:06-14:38 15 iterations of scan using CARM_SET_scan_FSR(numiteration = 15, f_FSR=110000,timescan = 60.)

14:40-15:12 15 iterations of scan using CARM_SET_scan_FSR(numiteration = 15, f_FSR=110000,timescan = 60.)

15:14-15:25 15 iterations of scan using CARM_SET_scan_FSR(numiteration = 15, f_FSR=110000,timescan = 60.) Unlock before the end

15:28-16:00 15 iterations of scan using CARM_SET_scan_FSR(numiteration = 10, f_FSR=110000,timescan = 60.)

 

Figures 1 and 2 show the evolution of the distance of each mode from the fundamental mode normalized by the FSR during the transient for the West and North cavities. The results form HG04 are constant for the time 11-41UTC, it correspond to the moment where the fourth order mode is at the same position than the sidebands at 56MHz. Further analysis will be done and presented in comment of this logbook including the meausrement of astigmaitsm during the transient and in-situ estimation of the RH calibration.