Reports 1-1 of 1 Clear search Modify search
Interesting data (Interesting data)
fiori, ruggi - 13:12 Thursday 16 June 2011 (29669) Print this report
combs OFF (!?)
since the lock of ~21:00 UTC June 14 (starting right after the 3kHz source investigations and the "recovery" actions listed here: 29666 and 29654) all the noisy combs see 9637 and 29553) disappeared from dark fringe. This results in a much reduced noise from 10Hz to 30Hz: see Figure 1. The VELA region cleaned significantly (see Figure 2: red and black show times with combs of different intensity, purple is now). In Figure 3: the days to beat the VELA spin down limit, which improved by about a factor tow with respect to when intense combs were present.
Images attached to this report
Comments to this report:
mabizoua - 17:27 Thursday 16 June 2011 (29673) Print this report
great!