swinkels, ruggi, tacca - 20:39 Monday 06 June 2011 (29559) Print this report
Baffle-noise due to earthquake?
While looking at data from Saturday's earthquakes, Paolo noticed that the sensitivity stays bad for almost 10 minutes, even though the quake is over and all suspension- and alignment-signals seems to have calmed down. A spectrogram of the dark-fringe shows there are some noise bumps which slowly decay in frequency starting from around 400 Hz. Our money is on scattered light by excited baffles. We had a look at fast spectrograms, but couldn't detect any arches. Also the seismometers on the detection tower and the cryotrap didn't show any excited resonance.