fiori - 16:18 Friday 06 May 2011 (29318) Print this report
lines with magnetic coherence
These are major lines below 100Hz which have some coherence with magnetic sensors. However, as derived from
Gabriele's coherence table
, for most of them the largest coherence is with other channels which I list on the side:

1) 10Hz harmonics (30,40,60,70,80,90Hz) mainly coherent with channels Ti_1PPS_Atomic, Ti_1PPS_GPS_Old Ti_1PPS_GPSMaster, TolmPhoton_processed_packets

2) line at 28.61 Hz: is coherent with NI tower seismometer Em_SETONT01 (0.46) and Sc_NI_tyCorr (0.33) ...

3) line at 29.05 Hz: with MC seismometer Em_SEBDMC03 (0.64) ...

4) line 36.54 Hz and its harmonic at 73.05 Hz: coherent with channels Pr_6MHz_WE_PhErr (0.83) Pr_6MHz_NE_PhErr (0.83) Bs_PMC_DR_DC_1 (0.68) Bs_PMC_DR_DCHF (0.67)

5) 43.70 Hz and its harmonic at 87.46 Hz : coherent essentially only with magnetometers Em_MABDWE01 (0.67), also see 29268

6) a triplet at 57.19 Hz, 57.43Hz and 57.83 Hz: are also coherent with Sc_NI_RM_CoilU (0.49) Ca_NI_RM_CoilR (0.38) ...

Figure shows the size in hrec of lines 44 and 88 Hz, and the 57Hz-triplet.