Online Computing (General)seder - 11:02 Monday 31 August 2026 (69672)
Print this reportdefault dataDisplayRoot6 changed on AL9 machines“dataDisplay” has been reverted from v11r3 to v11r2 in the Desktop Environment menu for the AL9 machines. This was done due to several reported bugs that will be fixed in the upcoming v11r4 release.
Comments to this report:
seder - 16:30 Tuesday 08 September 2026 (69711)
Print this reportThe default dataDisplay has been updated to the v11r4 release on AL9 machines
bersanetti - 20:41 Wednesday 09 September 2026 (69723)
Print this report
The problem of not displaying correctly channels at different sampling frequencies (specifically when a 1 Hz channel is involved) is still present; dataDisplay v11r4 doesn't crash anymore but the visualization still has issues.
Images attached to this comment
seder - 11:03 Tuesday 13 October 2026 (69908)
Print this reportThe default dataDisplay has been updated to v11r4p1 on all ctrl, farmn, and dev machines. This new patch contains a fix for the memory leak associated to the Update button.
In addition, the AL9 machines have changed the THP khugepaged/max_ptes_none configuration from 511 (AL9 default) to 64, to stop khugepaged from inflating idle dataDisplay processes to about 2 GB by filling their sparse heap with huge pages. These 2 changes should noticeable improve dataDisplay performance for users.
In order for the configuration change to take effect, users must close any active dataDisplay sessions.