Reports 1-1 of 1 Clear search Modify search
Vacuum (West input)
Vacuum - 20:07 Monday 09 March 2026 (68849) Print this report
WI turbopump failure
At about 19h30LT the WI turbomolecular pump went in failure and was automatically isolated. The spare unit was then put into operation, and normal conditions were restored at 20h00 LT.

The failed pump will have to be replaced during the maintenance break
Comments to this report:
Vacuum - 12:21 Tuesday 10 March 2026 (68854) Print this report

This morning we replaced the failed pump on WI.
About the disturbances observed yesterday evening , the failed pump was offline but still connected to the controller (failure of the magnetic bearing controller, replaced just after the shutdown), we can't exclude noisy effects due to the faulty electronics.