Reports 1-1 of 1 Clear search Modify search
AdV-DAQ (Calibration)
vanhove, mours, romboli, paoli, fabiozzi - 14:19 Thursday 20 November 2025 (68197) Print this report
NEB NCal systematics and survey

20/11/2025

This morning, we performed a geometrical survey of NEB NCals and swapped NEN and NWN rotors. Here below the details.

All times in UTC. Use notation as in wiki page

7:13 : Jigs placed on NE and NW platines between 7:13 and 7:14 (see position plot)

Positions of rotors before survey and changes:

-NWN : rotorbox 2021-06 (wiki table says this box contains R4-17)

-NEN : rotorbox 2022-01 (wiki table says this box contains R4-16)

~8:53 Start calibrating station 1 for measurement of East setup

~9:19:56 : NEF measure; --> fail?

remeasure calibrating points from 9:26:52 to 9:34:28

9:34:28 : NEF point

9:35:05 : NEN point ->9:35:49

9:36:34 : NET point --> 9:37: 16

9:37:50: point 210_aux (to check between stations)

9:42:33 : Start dismounting NCal NEN 

9:56:17 Start calibrating station 2 for measurement of West setup

10:00:07 sphere on NWF point

10:00:38 sphere on  NWN point 

10:01:34-49 move sphere back to NWF

10:02:35: move sphere to NWT --> 10:03:24

measure 210-aux and put rotorbox 2022-01 on NWN

10:08:35 measure NWN_swap; 10:09:22 measure NWF_swap - 10:10:05 measure NWT_swap -->

10:16:29 rotorbox installed on rotorbox 2021-06 on WEN

~10:23:01 start calibrate station 3 for East "swap" measurement

10:25:38 NEF -> 26:13-26:21 NEN -> 26:46-27:14 NET ->27:45-28:04 210_aus 28:54

Remove jigs from East setup (10:29:39-10:30-15)

WEB_pos_sensors.png shows the position measurement of East and West setup during all the today work

11:00 unexpected LV problem for NNN observed: 32V gives 0 current.

  • change it from channel 1 ncal east Power Ssupply to channel 2 ncal south Power Supply
  • It did not fix the problem unfortunately

11:05 we restart all rotors (except NNN which is not spinning) at twice the nominal frequency and leave 

 

 

Images attached to this report
Comments to this report:
a.paoli - 19:43 Thursday 20 November 2025 (68208) Print this report

The result of the NE survey is reported in the entry 68206

masserot, mours - 20:14 Tuesday 25 November 2025 (68251) Print this report

The rotor parameters of NWN and NEN have been swapped and the NEB_NCal configuration reloaded at 17:27 UTC, following the rotors swap of last week. The NWN control parameters have readjusted at 19:09, since they seems to be more related to the controler, than the rotor itslef.

vanhove - 16:24 Wednesday 03 December 2025 (68303) Print this report

In this log entry, we use the following naming convention for surveyed points (three per platines): 

Each platine is named after the first two letters of the near rotor + 1 character which is "T" for the point above the rotor, "N" for the surveyed point nearest to the Near rotor, "F" for the last surveyed platine point (further away fro the near rotor)

The "transation" between  this convention and the one from the log entry 68206 is as follows:

NET = NE_Ncal_EB_05T
NEN = NE_Ncal_EB_03-SW
NEF = NE_Ncal_EB_02-SE

NWT: NE_Ncal_WB_05-T
NWN: NE_Ncal_WB_01-NE
NWT: NE_Ncal_WB_04-NW