ITF found at CARM_NULL_1F in TROUBLESHOOTING mode waiting for Violin modes to subside. PSTAB loop still open.
Unlocks due to IMC unlock (UTC):
- 21:12 unlocked due to diverging SSFS corr. Automation reached CARM_NULL_1F again on first attempt at 21:25.
- 21:45 unlocked with too much power on B7 and B8.
- 21:58 unlocked at LOCKING_CARM_NULL_3F. Reached CARM_NULL_1F on first attempt at 22:11.
- 22:25 again due to diverging SSFS corr. INJ On-call (Spinicelli) notified.
- 02:52 at FMODERR_TUNED
Attempted to lock in LN3 at 02:20UTC: LN2 achieved at 02:30UTC, unlocked at 02:31UTC due to Diffp oscillation (pdf 1). Automation reached LOCKING_CARM_NULL_3F before unlocking twice in the same way at 02:41 and 02:51UTC with SDB2_B1p_QD1 horizontal and vertical loops open. Unlocked in LOCKED_CARM_MC_IR at 03:04UTC with B1p_QD1 horizontal loop open. Then systematically in LOCKING_CARM_MC_IR at 03:12, 03:20 and 03:28UTC with both horizontal and vertical loops open (DMS plots in fig.2 and 3.)
Unlocked in LOCKING_CARM_NULL_3F at 03:37UTC and then in LOCKING_CARM_MC_IR at 03:45UTC. DET On-call (Was) notified as I cannot find a way to close B1p Quadrants loops beyond lock of CITF. (DMS plot in fig.4)
03:55 - 04:50UTC Attempted step by step lock acquisition twice up to LOCKED_CARM_MC_IR to isolate the issue. ITF keeps unlocking systematically (04:25 and 4:45UTC) beyond that point, so I parked it in LOCKED_ARMS_BEAT_DRMI_3F waiting for expert intervention.
05:19UTC After cross alignment of SR with assistance from Berni and Was, lock acquisition towards CARM_NULL_1F finally progressed up to CARM_NULL_3F, before unlocking again at 05:25UTC. Relocking in progress.
Guard tour (UTC)
-> 21:29
23:06 -> 23:50
01:15 -> 01:56
03:20 -> 03:56
DET
21:59-22:06UTC SDB2_B1p_QD1 and QD2 Vbias rearmed and Shutter opened during lock acquisition 3.
02:42-02:47UTC SDB2_B1p_QD2 Vbias rearmed and Shutter opened.
21:59-22:06UTC SDB2_B1p_QD1 and QD2 Vbias rearmed and Shutter opened.
04:39UTC SDB1 LC floating setpoints disabled by Was for Galvo quadrant intervention.