Implementation of SQZ coherent control loop and effect on quantum noise
Tonight we tested the coherent control loop as we did in the past (seen entry 41556). With the ITF in low-noise 3 and the SQZ source set to squeezed vacuum, we connect the 7 MHz demodulation of the B1 PD! to the tuning voltage of the frequency synthesizer serving as local oscillator for the external SQZ PLL.

We coarsely tuned the loop parameters (gain and offset of error signal) to make the loop stable without measuring the TF. Then we tuned the demodulation phase in order to maximize the effect of anti-squeezing on DARM noise. Detected anti-squeezing is now aroung 5.5 dB, higher than yesterday because of the reduced phase noise. We then changed the phase by 90 deg to inject phase squeezing.

Fig 1 shows the DARM and Hrec spectra in three different conditions: with the SQZ fast shutter closed (purple), with injected anti-squeezing (orange) and with injection of squeezing (blue). Differently from the effect of anti-squeezing, the effect of squeezing is barely visible, probably due to a combination of the large residual phase noise and of possible extra misalignment losses.

We also characterized the 7 MHz PLL which locks the B1 demodulation frequency to the local oscillator for the SQZ PLL.
Fig 2 shows
- the CC error signal (SQZ_B1_PD1_7MHz_I),
- the derivative of the phase extracted from SQZ_PLL7 monitoring (SQZ_PLL_7MHz_raw_dFreq), which is used as error signal for the 7MHz phase loop
- the coherence between these 2 signals
in the following conditions
- Blue: CC error signal gain equal to 1 and 7MHz phase loop closed
- purple: CC error signal gain equal to 0.5 and 7MHz phase loop opened
One can see that
- with a gain of 0.5 the bump above 100 Hz decreases
- with 7MHz loop open there is no major modification of coherence and the coherence remains at the same high level in the 7-30Hz region : to be investigate

We spent the remaining time to characterize the alignment error signals from B1p quadrants. We closed the SQZ fast shutter at 4:32. ITF is left in LN3, and the SDB1 Faraday shutter is left open to avoid unlocking.
Images attached to this report
Comments to this report:
mours - 8:51 Thursday 15 November 2018 (43583) Print this report

Searching for the time with lowest level of noise using band rms in the 2.0-2.1 kHz, here is the spectrum for 1 second of data (blue), compared to a time when the squeezed beam was not injected (purple line). On this very specific 1 second of data (lowest level of noise floor), there is maybe a 10% reduction of the shot noise level.

Images attached to this comment
Search Help
×

Warning

Error

The present report has been modified outside this window. Please check for its integrity in the main page.

Refreshing this page will move this report into drafts.

×