Study of bilinear noise in DARM around Mains lines

We performed an analysis similar to that described in 42880. The bumps around Mains harmonics (the bumps are especially large at odd harmonics: 150Hz, 250Hz350Hz, 450Hz  but are present also around even harmonics: 200Hz, 300Hz, 400Hz) are correlated in blind way with the low frequency component (<10Hz) of several signals (including ASC*, SBE_*LC*, Sc_*, LSC_B*_DC, SDB2_B*_PD*_56MHz*) . The channel list and the results are posted below.

We find signals ASC_DIFFp_TY and SDB2_B1s1_PD1_56MHz_I   seem to explain well most of sidebands.