Reports 1-1 of 1 Clear search Modify search
AdV-PAY (NE and WE Payloads)
majorana - 15:32 Thursday 04 January 2018 (40330) Print this report
NE status
Yesterday the NE vacuum chamber was open and The payload room was accessed.

The position of the marionette meant to reproduce the angular reference gathered by the focal plan optical lever impinging on the mirror was obtained using the marionette control.
Notice: no sensor on both marionette and mirror has been displaced (only the image plane one used to damp the mirror).
The data are recorded in Sc_NE_MIR_PSD_X2 and Sc_NE_MIR_PSD_Y2 (They are non normalised asymmetries in fine mode, notetice that due to technical reasons the probe of the reconstructed angle is absent, but the information is the same) FIG 1.

In this situation we recovered the alignment of the HS SLED beam of TCS ( a separate entry will appear about this topic ).

In the evening I spent some time trying attain the balance keeping the balance motor slides .
Unfortunately, due to technical reasons I did not succede and today I set again the system suing the motor balancing.

Anyhow, at present the information about the control offset meant to control the marionette around the aligned position of the mirror is recorded in Marionette control DSP card.
Later I will centre the marionette control zero in order to attain the same mirror position working around its zero.

I observed an unpleasant view of the mirror as I took few pics during the work. The time I illuminated the mirror using a strong led illuminator on my head.

FIG 2 : from side OK
FIG 3 : AAAAHHHGH Jeopardised spots at 45 deg incidence ! That's the first contact certainly because getting close to the mirror one can easily observe its contours

Probably they have no effect....


Images attached to this report
Comments to this report:
majorana - 18:20 Thursday 04 January 2018 (40333) Print this report
Vacuum just started,

- LC majorette closed Tx Ty Tz zDamp
- F7 Ty
- F0 Position X,Z,Ty

GUARD
majorana - 23:05 Friday 05 January 2018 (40342) Print this report
Since lunch time NE status is

-F0 Hor ID ON
-F0 Ver ID OFF
- F0 GUARD ON

- F7 tilt DAMP ON
- F7 GUARD ON

- PAY LC ON
- GUARD ON

NOTICE: Mario OpLev has been readjusted in order to keep the mirror in the aligned position (now the offset in the DSP Mar control is 0)

- No change in ctrl filters

- The loops will be opened (leaving only F0 Pos ON on Sunday 7/January) before the venting needed by VAC operation (postponed to Sunday Morning)

What remains: -touching the OpLev for Mario control very probably the PSD is not anymore precisely located on focal plane, that must be revised
- Voltage offsets on H F0 control should be removed using the motors
Images attached to this comment
majorana - 8:16 Sunday 07 January 2018 (40344) Print this report
Now the controls at NE site are OPENED, to allow the venting of the vacuum chamber.
Search Help
×

Warning

Error

The present report has been modified outside this window. Please check for its integrity in the main page.

Refreshing this page will move this report into drafts.

×