Detection servers configuration update to rename the B5_QD2 channels as B1s_QD1 channels

The quadrant photodiode acquiring previously the B5_QD2 beam is now used to acquire the B1s_QD1 beam .

To be compliant with the new name of the beam, we  proceeded with the renaming of the B5_QD2 channels to B1s_QD1 channels .

The operations were performed between 2026-09-08-06h39m28-UTC and 2026-09-08-09h18m52-UTC 

Below the details of the operations performed:

  • SDB2_dbox_bench server
    • DBox SN106 - demodulation mezzanine SN87
      • rename  as SDB2_DEMOD_B1s_QD1 instead of  SDB2_DEMOD_B5_QD2 previously
      • add the demodulation of the B1s_QD1 beam at  6MHz, 50MHz, 56MHz and 112MHz  for the 4 quadrant sectors
    • DBox SN007 - ADC2378 mezzanine SN43
      • renamed as  SDB2_ADC_B5_B1s_QD instead of SDB2_ADC_B5_QD previously
      • add the readout of the B1s_QD1_{H,V,SUM} channels  instead of the B5_QD2 ones
  • SDB2_Tpro server and SDB2_ Fb server
    • Replace the old Tolm packets' name by the new ones
  • SDB2_Quadrants  server 
    • Remove all the functionalities related to the B5_QD2 quadrants channels 
    • Add the last part of the demodulation of the B1s_QD1_{6,50,56,112}MHz channels
    • Add the B1s_QD1 galvo loops part
  • SDB2_readout server
    • swap the B5_QD2 channels with the B1s_QD1 ones
  • QPDMoni server
    • change the name associated to the interface ethmt7-2011 as B1s_QD1 instead of B5_QD2
  • ASC_Acl server
    • the internal channels labelled B1s_QD1 are build using the SDB2_B1s_QD1 input channels
    • the internal channels labelled B1s_QD2 are build using the EDB_B1s_QD2 input channels
    • the B5_QD2 channels used in the TX_SENSING matrix and in the TY_SENSING matrix have been replaced by the B1s_QD1 respective channels
  • Automation servers. ARMS_LOCK, DRMI_LOCK,
    • The related python config files have been updated by commenting the parts related to the SDB2_B5_QD2 quadrants 
  • DetMoni server
    • all the parts related to the B5_QD2 quadrant photodiode have been commented
    • the monotoring part related to the B1s_QD1  quadrant photodiode have been added and remains to be tuned
    • A new flag B1s_QD1 has been in the DMS interface : the DMSserver server has been restarted to take in account this modification

 

Comments to this report:
gouaty - 18:18 Tuesday 08 September 2026 (69713) Print this report

The thresholds used for the definition of the QPD_B1s flag have been update in DetMoni. The checks on the B1s centering and the status of the galvo loop will be performed only after the state "SHUTTER OPEN".