ITF found in locked arms.
At around 7:00 with Piernicola we went to NE to reactivated the green laser then the commissioning team recovered the DRMI state, see 69700.
Once recovered the ISYS team started working to reduce the input power.
ISC
Etalon setpoints changed and loops enabled:
2026-09-07 09h02m42 UTC berni 'WI:WI Set point [WI_RH_SET=19.15,rampTime=1]' sent to LSC_Etalon_Acl
2026-09-07 09h02m45 UTC berni 'WI:Enable servo' sent to LSC_Etalon_Acl
2026-09-07 09h02m52 UTC berni 'NI:NI Set point [NI_RH_SET=19.53,rampTime=1]' sent to LSC_Etalon_Acl
2026-09-07 09h02m53 UTC berni 'NI:Enable servo' sent to LSC_Etalon_Acl
TCS
In the first part of the shift Cecilia worked at TCS TCS AuxCooling System, see entry 69697.
DAQ
At around 1:20 UTC we had a general loss of data: the data from Suspensions and TCS did not recover. At 13:44 UTC I contacted the DAQ on call; investigation in progress.