Reports 1-1 of 1 Clear search Modify search
Injection system (General activities)
lagabbe, gosselin, zaza - 18:05 Wednesday 26 August 2026 (69654) Print this report
Chiller of the neovan electronic has been exchanged

The chiller of the neovan electronics stopped working at around 14:00 utc. Probably due to normal device aging.

This afternoon we exchanged the chiller with the spare that was in the optics lab. The serial number of the old chiller is on the pictures attached to this post.

PS: In the chiller water tank, we found some 'sand' which is probably some metal oxide and particle coming from the electronic devices and tubing.

Images attached to this report
Comments to this report:
lagabbe, zaza, spinicelli - 16:25 Thursday 27 August 2026 (69662) Print this report

This afternoon around 14h20 local, we increased the chiller temperature setpoint from 16 C to 17 C, and increased the water flow.

Images attached to this comment