Reports 1-1 of 1 Clear search Modify search
Vacuum (Cryo Trap)
Vacuum - 13:27 Monday 13 April 2026 (68987) Print this report
Cryotrap NI extraordinary maintenance
the NI cryotrap has been isolated by closing both large vacuum valves at its extremities. Its refill system has been stopped, as a preparation for the substitution of the leaking bellows.
Comments to this report:
Vacuum - 10:57 Saturday 02 May 2026 (69060) Print this report
Follow-up of the repair: in the past few days the suspected part was dismounted and inspected in Lab (pictures): a large leak has been detected on some welds.

The spare part has been installed and then the pumpdown was started. The cryotrap is now under high vacuum, and the cooldown is foreseen from next tuesday.
Images attached to this comment
Search Help
×

Warning

Error

The present report has been modified outside this window. Please check for its integrity in the main page.

Refreshing this page will move this report into drafts.

×