Reports 1-1 of 1 Clear search Modify search
Detector Operation (Operations Report)
gherardini - 21:52 Tuesday 17 March 2026 (68893) Print this report
Operator Report - Afternoon shift
The work inside the injection area went on in the first part of the afternoon (#68892), at around 18:00UTC we started to relock the ITF, it relocked at CARM_NULL_1F at the first attempt and the work on squeezing went on in this configuration; activity completed at 20:30UTC, then the ITF was locked up to LOW_NOISE_3, I left it locked with the failsafe engaged.
Images attached to this report
Comments to this report:
bersanetti - 0:00 Wednesday 18 March 2026 (68894) Print this report

Tonight I found the ITF stuck in DOWN, as the bug impacting the autorelock failsafe of the ITF_CONDITIONS node is still present. I put that node in STOP and the lock acquisition restarted automatically.

Please do not engage the autorelock failsafe until the bug is found and dealt with.

Search Help
×

Warning

Error

The present report has been modified outside this window. Please check for its integrity in the main page.

Refreshing this page will move this report into drafts.

×