Reports 1-1 of 1 Clear search Modify search
Detector Operation (Operations Report)
zaza - 22:53 Monday 09 March 2026 (68844) Print this report
Operator Report - Afternoon shift

ITF still in recovery - TROUBLESHOOTING at the beginning of the shift, which kept on going through the afternoon
Here  the steps taken during the recovery and the edits to automation (Pinto, Spinicelli, Nardecchia, Was, Ruggi). LN2 was achieved three twice (18:30 UTC - vac pump failure, 19:57 UTC) lasting only a few minutes in both cases.
18:30 UTC Vacuum pump failure, fixed (Vacuum Team)
20:43 UTC ITF in LN2
20:56 UTC unlock, 
then unlock at LOCKING_CARM_NULL_1F (21:06 UTC), REDUCING_CARM_OFFSET_2_OF_3 (21:20 UTC), LOCKING_CARM_NULL_1F (21:30 UTC)
At the end of the shift, as instructed, I left the ITF in LOCKED_ARMS_IR - TROUBLESHOOTING, since it had not been possible to keep a stable lock in LN2 or to reach CARM_NULL_1F during the other locking attempts.

Images attached to this report
Comments to this report:
pinto - 23:55 Monday 09 March 2026 (68850) Print this report

After the WI pump failure, WI suspension is moving quite a lot, more with respect to the usual, fig.1.

I don't know if this is related to the failed locking attempts, tomorrow the problem will be better addressed.

Images attached to this comment