Reports 1-1 of 1 Clear search Modify search
AdV-TCS (CO2 laser projector)
sorrentino - 9:35 Monday 24 November 2025 (68229) Print this report
Carrier contrast defect vs DAS tuning

The attached plot shows an example of the impact of DAS tuning on carrier contrast defect. Carrier contrast defect is computed as the ratio of calibrated B4 power to calibrated B1p carrier power, where the fraction of carrier in B1p is extracted from the B1p phase camera. Data refer to the DAS tuning done after WE mirror replacement, and span from June 10 to August 17 2025, i.e. after the ETM RH tuning was over. 

Images attached to this report
Comments to this report:
sorrentino - 16:16 Monday 24 November 2025 (68233) Print this report

Here's another example dating back to input laser changes in early 2024, when a 50% improvement in contrast defect follwed a tuning of WI DAS power.

Images attached to this comment
Search Help
×

Warning

Error

The present report has been modified outside this window. Please check for its integrity in the main page.

Refreshing this page will move this report into drafts.

×