Reports 1-1 of 1 Clear search Modify search
Environmental Monitoring (Environmental Monitoring)
Fiori, Paoletti, Tringali - 12:59 Tuesday 14 October 2025 (67934) Print this report
Installation of accelerometer near CEB velocimeter

This morning, we installed an accelerometer near the velocimeter (Guralp) in the CEB hall, Figure 1 and Figure 2:

TCS room - CEB_ADC7674_1, SN 56, channel 10
name: ENV_CEB_ACC_V

The purpose is to monitor the vibration of the floor during the acoustic injections at high frequency (above ~200 Hz).
A comparison between the spectra of the velocimeter (red curve) and the accelerometer (blue curve), as well as their coherence, is shown in Figure 3.

Images attached to this report
Comments to this report:
Paoletti - 6:57 Monday 24 November 2025 (68227) Print this report

Note that the Coeherence between the two nearby sensors (ENV_CEB_SEIS_V and ENV_CEB_ACC_V) is reduced during the acoustic injection in CEB

Images attached to this comment
Search Help
×

Warning

Error

The present report has been modified outside this window. Please check for its integrity in the main page.

Refreshing this page will move this report into drafts.

×