Reports 1-1 of 1 Clear search Modify search
AdV-DAQ (Data collection)
masserot - 8:57 Wednesday 08 October 2025 (67884) Print this report
DAQ : BaDAQ server

As data collection of the IMC baffle made by the BaDAQ server has not  been restored  since the end of June 2025 (see the plot) :

  • it has been set as optional in the VPM configuration
  • it has been removed from the list of expected sources at the FbmAlp server level 
    • this server provides a channel related to  the latency of each source  called  Daq_FbmAlp_<source_name>_latency
    • when an input source is missing it latency channel is set to 0.
Images attached to this report
Comments to this report:
ballester, masserot - 10:30 Wednesday 08 October 2025 (67886) Print this report

The BaDAQ server has been restored by Otger.

As a consequence, the previous actions were reversed 