Reports 1-1 of 1 Clear search Modify search
AdV-ISC (Commissioning up to first full interferometer lock)
mantovani - 9:25 Thursday 03 July 2025 (67202) Print this report
increase of the range

Yesterday we observed an other strange increase of the Range

the interesting thing is that is correlated with the inverse of the power on B1p, as for the event of the 20th of Jun. See figure 1 and 2. this time no correlation with a kick on SR tx.

to be understood.

Images attached to this report
Comments to this report:
mantovani, spinicelli - 15:37 Thursday 03 July 2025 (67204) Print this report

also the B4 12MHz show a correlation with the range. Moreover also the coupling of frequency noise has a strong correlation with the BNS, but in a strange way... the higher is the coupling the better is the range (figure 2 and 3). The origin of the trend has not be found yet

Images attached to this comment
Search Help
×

Warning

Error

The present report has been modified outside this window. Please check for its integrity in the main page.

Refreshing this page will move this report into drafts.

×