Reports 1-1 of 1 Clear search Modify search
AdV-DAQ (Calibration)
vanhove, mours, masserot - 9:52 Tuesday 21 January 2025 (66017) Print this report
Restart and Check of NCal control using relative thresholds with new acl version
During this morning maintenance, the acl version has been updated to v1r35p17 that enables relative thresholds for the control of rotor frequencies.
After acl update, We first restarted successfully the setup with previous absolute threshold.
Then we moved to relative threshold with following lines

define {ROTOR-REL-PARAM} "1 0.01 0.1 0.5 0.95" in "NEB_NCal.cfg"
ACL_PULSE_CH_OPTION {NCAL}_rotor ncal {ROTOR-REL-PARAM} in "NEB_Ncal_shared.cfg"

With this new setting, all rotors successfully reached their nominal frequencies and phases.