Virgo Runs (O4b)
amagazzu - 23:54 Friday 03 January 2025 (65918) Print this report
Operator Report - Afternoon shift

ITF found during locking acquistion, at 14:41 UTC I manually unlock to allow Spinicelli to further improve the alignement on the Laser Bench. The activity was concluded at 17:35 UTC and it was possible to relock again. Unfortunately the ITF was unstable and unlocked at various steps of the locking acquistion, all of them above LOCKING_CARM_NULL_1F. Also at 19:06 UTC the valve of one of the MC Pump closed.
At 20:25 UTC I contacted the DET Oncall to investigate a possible issue with too much power on B1/B1p, in parallel at 20:59 UTC the ITF reached stably LOW_NOISE_3. The ITF was kept in troubleshooting mode to allow the Vacuum Expert (Macchia) to solve the issue with the pump inside the Mode Cleaner building.
ITF left locked in LOW_NOISE_3 and in Science Mode.

Oncall events

DET
(03-01-2025 20:25 - 03-01-2025 21:45) From remote
Status: Ended
Description: During the afternoon the ITF kept unlocking at various steps of the locking acquisition.
Actions undertaken: I've contacted the DET Oncall (Gouaty) hoping to investigate if the issues could be related to extra power in B1/B1p. Gouaty verified that the behavior of the subsystem was nominal, and that the unlocks were not caused by the Fast Shutter of the engagement of SDB1 Drift Control.

Vacuum
(03-01-2025 19:10 - 03-01-2025 22:00) On site
Status: Ended
Description: At 19:06 UTC one of the Valve of a pump inside the Mode cleaner building closed.
Actions undertaken: I've contacted the The VAC Oncall (Macchia), who came on site to investigate the issue. Unfortunately it was not possible to restart the pump.

Images attached to this report
Comments to this report:
narnaud - 0:04 Saturday 04 January 2025 (65921) Print this report

Statistics is limited but it is clear that Piernicola's work has improved the situation a lot glitch-wise -- see Omicron plot in attachment.

Images attached to this comment
Vacuum - 9:53 Saturday 04 January 2025 (65923) Print this report

The MC turbomolecular pump went in failure (on 03/01 at 20h05 LT) and needs to be replaced. The replacement is planned for the next Tuesday break.

Vacuum - 16:20 Tuesday 07 January 2025 (65943) Print this report

Today morning we reactivated the MC pump after replacing its onboard electronics. We have added a fan (picture), temporarily, to control its thermal trend

Images attached to this comment