/virgoLog full at 90%

Fabio reports that

After some investigations, we found that the culprit was the SatServer : clicking on the button "Activate WARNING logging" allows to reduce a lot the log rate : operation performed at 2024-12-18-21h30m52-UTC .

The biggest SatServer log files have been moved into the data/dev/logs/VirgoOnline/SatServer directory to recover a correct usage of the /virgoLog area

Images attached to this report
Comments to this report:
bersanetti, carbognani, masserot - 9:28 Friday 20 December 2024 (65847) Print this report

We added in the INIT and DOWN states of ITF_LOCK a cm command to set the WARNING log level to SatServer.