Reports 1-1 of 1 Clear search Modify search
Environmental Monitoring (Environmental Monitoring)
Tringali, Fiori, Paoletti - 12:46 Tuesday 17 December 2024 (65823) Print this report
Comment to Acoustic injection in NEB and WEB (61566)

This morning, we prepared the setup for the acoustic injections at WEB, scheduled for Thursday. Below are the parameter values (in bold) for the acoustic injections using the VPM ENVnoise process:

********************************************************************************************************************
# nameOut - unit - rampTime - samplingFreq - density - seed
ACL_NOISE_CH                noise_white            "V"     5    SAMP_FREQ    1.  
ACL_FILTER_CH                noise_colored        "V"    5    SAMP_FREQ    noise_white    0.004    "flt3"
********************************************************************************************************************

 

These values have to be set to 0.0 and 0.04 for the automated CEB acoustic injection with the Metraton node ENV_MAIN:
********************************************************************************************************************
# nameOut - unit - rampTime - samplingFreq - density - seed
ACL_NOISE_CH                noise_white            "V"     5    SAMP_FREQ    0.0  
ACL_FILTER_CH                noise_colored        "V"    5    SAMP_FREQ    noise_white    0.04    "flt3"
********************************************************************************************************************

The next step will be implementing automated acoustic injections in the terminal buildings.

Images attached to this comment
Search Help
×

Warning

Error

The present report has been modified outside this window. Please check for its integrity in the main page.

Refreshing this page will move this report into drafts.

×