Reports 1-1 of 1 Clear search Modify search
Virgo Runs (O4b)
gherardini - 14:59 Monday 16 December 2024 (65813) Print this report
Operator Report - Morning shift

This morning the ITF unlocked from science at 7:06UTC, the following LOW_NOISE_3 locks lasted only few minutes with the longer science mode of about 18 minutes, the lock acquisition worked fine the ITF relocked each time at the first attempt , Manuel worked to understand the problem, in the last lock which is still ongoing he disabled the BS and PR ID reallocation.

Sub-system reports

SBE
at 8:49UTC the SPRB position loop was opened by the guardian, controls properly closed.
recovery of SQB1 vertical correction with F0 step motors from 9:40UTC to 9:35UTC.

Images attached to this report
Comments to this report:
Paoletti, Fiori, Tringali - 15:36 Monday 16 December 2024 (65818) Print this report
Images attached to this comment
pinto - 16:37 Monday 16 December 2024 (65819) Print this report

Given the time coincidence of the excavator moving near the central building there's a possibility of correlation with the unlocks/ mulfonctioning of the reallocation strategy at the central suspensions.

The reallocation engagement will be enabled if at the next unlock it will be reloaded ITF_LOCK metatron node.

Search Help
×

Warning

Error

The present report has been modified outside this window. Please check for its integrity in the main page.

Refreshing this page will move this report into drafts.

×