Comment to Operator Report - Afternoon shift (65217)

Today the ITF unlocked continuously along different step of the acquisition, the few times it was able to go towards the final steps of the acquisition (Low Noise 2), it unlocked sistematically due to the 400 mHz oscillation, well visible in the fringe, which became too bright. This oscillation seems affecting BS TX, which starts to oscillate up to divergence right after the switch of the control loop to 'full bandwidth'. This has an effect also on SDB1 detection bench, along TX (Fig.1).

For the time being, the engagement of the full bandwidth mode in LN2 has been commented (line 5862 ITF_lock.py).

The ITF keeps unlocking in different places -> microseism and wind activity (not high since this late morning) in the decreasing phase (Fig.2).

400 mHz still quite high with rescpect to yesterday (Fig.3).

Several unlocks at CARM null 1f not clear...will be better investigated.