Reports 1-1 of 1 Clear search Modify search
AdV-ISC (Commissioning up to first full interferometer lock)
mantovani, pinto, ruggi - 10:11 Thursday 25 July 2024 (64782) Print this report
New controller for NI etalon loop

this morning the new controller for the NI has been updated after having re-evaluated the plant for NI (see entry https://logbook.virgo-gw.eu/virgo/?r=64736 )

the new controller is

# Etalon North boost 02
ACL_FILTER_SET      Etalon_north_boost_02    1        35000    1    10
ACL_FILTER_ZEROS    Etalon_north_boost_02    2e-07    0
ACL_FILTER_ZEROS    Etalon_north_boost_02    2e-06    0.6
ACL_FILTER_POLES    Etalon_north_boost_02    0        0
ACL_FILTER_POLES    Etalon_north_boost_02    0        0
ACL_FILTER_POLES    Etalon_north_boost_02    1e-5    0

Moreover the down conditon for long unlocks (like this commissioning break) is not optimal and it is better to discharge the offset at least once a day.

 

Comments to this report:
mantovani - 15:19 Thursday 25 July 2024 (64786) Print this report

In any case I've decreased of a factor 10 the gain of the filter for the NI and WI down condition to reduce the effect (to be improved once we will be again in working condition).