Reports 1-1 of 1 Clear search Modify search
AdV-ISC (Commissioning up to first full interferometer lock)
mantovani, pinto, ruggi - 10:11 Thursday 25 July 2024 (64782) Print this report
New controller for NI etalon loop

this morning the new controller for the NI has been updated after having re-evaluated the plant for NI (see entry https://logbook.virgo-gw.eu/virgo/?r=64736 )

the new controller is

# Etalon North boost 02
ACL_FILTER_SET      Etalon_north_boost_02    1        35000    1    10
ACL_FILTER_ZEROS    Etalon_north_boost_02    2e-07    0
ACL_FILTER_ZEROS    Etalon_north_boost_02    2e-06    0.6
ACL_FILTER_POLES    Etalon_north_boost_02    0        0
ACL_FILTER_POLES    Etalon_north_boost_02    0        0
ACL_FILTER_POLES    Etalon_north_boost_02    1e-5    0

Moreover the down conditon for long unlocks (like this commissioning break) is not optimal and it is better to discharge the offset at least once a day.

 

Comments to this report:
mantovani - 15:19 Thursday 25 July 2024 (64786) Print this report

In any case I've decreased of a factor 10 the gain of the filter for the NI and WI down condition to reduce the effect (to be improved once we will be again in working condition).

Search Help
×

Warning

×