Reports 1-1 of 1 Clear search Modify search
AdV-INJ (IMC Mode Matching Telescope)
derossi, gosselin - 14:33 Wednesday 05 June 2024 (64439) Print this report
ITF mode matching measurement

Yesterday we measured the matching to the hot ITF by giving a kick at the end mirrors (after more than 1h lock).

The GPS is 1401541068 and we left free swinging for 5 min.

We found 1,7% mismatch for the West arm and 2,1% for the North.

Images attached to this report
Comments to this report:
derossi - 17:28 Thursday 06 June 2024 (64450) Print this report

We made today another measurement with the kick (starting at around 14:40:00 UTC) and we found 3.6% for the north and 1.7% mismatch for the west.

Images attached to this comment
Search Help
×

Warning

Error

The present report has been modified outside this window. Please check for its integrity in the main page.

Refreshing this page will move this report into drafts.

×