Reports 1-1 of 1 Clear search Modify search
AdV-COM (AdV commissioning (1st part) )
masserot - 15:52 Tuesday 04 June 2024 (64420) Print this report
Sc_WI : Timing issue

This morning,  the channel monitoring the arrival time of the Sc_WI DSP  jumps from 10-15us to  67-72us (see the attached plot), as consequence the  DMS Timing_dsp  became red

At the same time period, the SUSP_Fb TolmFrameBuilder reports the following lines

2024-06-04-07h37m35-UTC>WARNING-[TolmFrameBuilderFrontEnd] Sc_WI: packet rejected: merging already done (packet: 1401521873.1004913890 < frame in construction: 1401521874.000000000) (49 times)
2024-06-04-07h37m36-UTC>ERROR..-[TfbSource::StoreData] producer Sc_WI: overflow at GPS 1401521874.199988880 (received 2001 / expected 2000) (61 times)
2024-06-04-07h37m36-UTC>WARNING-[TfbSourceManager::Merge] Times are different: dt: 0.200000-0.200000 / GTimeN: 0-1000000000 / GTimeS: 1401521874-1401521873
2024-06-04-07h37m37-UTC>WARNING-[TolmFrameBuilderFrontEnd] Sc_WI: packet rejected: merging already done (packet: 1401521874.1081887540 < frame in construction: 1401521875.000000000) (818 times)
2024-06-04-07h37m37-UTC>WARNING-[TolmFrameBuilderFrontEnd] Sc_WI: packet rejected: merging already done (packet: 1401521874.1995088790 < frame in construction: 1401521875.800000000) (9132 times)
2024-06-04-07h37m37-UTC>WARNING-[TolmFrameBuilder::ControlMerging] frame: 1401521875.000000000: merging is triggered on timeout (internal 1401521875.360415040 > max 1401521875.360000000)
2024-06-04-07h37m37-UTC>WARNING-[TfbSubFrame::Fill] GPS: 1401521875.000000000 - Source Sc_WI: 1999/2000 missing packet(s), 0 data break(s) (missing data are at the end of the vector)
2024-06-04-07h37m37-UTC>WARNING-[TfbSourceManager::Merge] Times are different: dt: 0.200000-0.200000 / GTimeN: 0-1000000000 / GTimeS: 1401521875-1401521874
2024-06-04-07h37m38-UTC>ERROR..-[TfbSource::StoreData] producer Sc_WI: overflow at GPS 1401521876.199972090 (received 2048 / expected 2000) (2928 times)
2024-06-04-08h17m15-UTC>WARNING-[TolmFrameBuilder::ControlMerging] frame: 1401524253.000000000: merging is triggered on timeout (internal 1401524253.361715080 > max 1401524253.360000000)

This channel is only a monitoring channel, used to check the correct DSP cycles running conditions. Up to now there is none logbook entry reported any activity of this DSP, so it's maybe an issue

Images attached to this report
Comments to this report:
poulton - 16:17 Friday 07 June 2024 (64456) Print this report

It seems a different issue happened with SUSP_Fb at around 12:42 yesterday:

2024-06-05-12h42m58-UTC>INFO...-[TolmFrameBuilder::FrontEnd] source Sc_WI (64:v05) is back (after a stop or a FIFO reset) -> acquisition will resume at the next start-of-second
2024-06-05-12h42m59-UTC>INFO...-[TolmFrameBuilder::FrontEnd] source Sc_WI (64:v05) start acquisition aligned with the start-of-second
2024-06-05-12h42m59-UTC>ERROR..-[TfbSource::StoreData] producer Sc_WI channel Sc_WI_MIR_COIL_FLAG: substitution of missing data is over frame bound (16718 extra value(s)) (61 times)
2024-06-05-12h42m59-UTC>ERROR..-[TfbSource::StoreData] producer Sc_WI: overflow at GPS 1401626597.999914060 (received 2745 / expected 2000) (45445 times)
2024-06-05-12h42m59-UTC>INFO...-[TfbSourceManager::Reporting] Sources reporting: / nSrc: 63
2024-06-05-12h42m59-UTC>INFO...-CfgReachState> Golden(Golden) Ok
2024-06-05-12h43m50-UTC>WARNING-[TolmFrameBuilder::ControlMerging] frame: 1401626648.600000000: merging is triggered on timeout (internal 1401626648.962015100 > max 1401626648.960000000)
2024-06-05-12h43m50-UTC>WARNING-[TfbSubFrame::Fill] GPS: 1401626648.600000000 - Source Sc_WI: 1/2000 missing packet(s), 0 data break(s) (missing data are at the end of the vector)
2024-06-05-12h43m51-UTC>INFO...-[TfbSourceManager::Clean] source Sc_WI (64:v05) has stopped -> waiting for data...
2024-06-05-12h43m51-UTC>INFO...-[TfbSourceManager::Reporting] Sources reporting: / nSrc: 62, missing(1): Sc_WI
2024-06-05-12h43m51-UTC>INFO...-CfgReachState> Active(Active) Ok
2024-06-05-12h44m08-UTC>INFO...-[TolmFrameBuilder::FrontEnd] source Sc_WI (64:v05) is back (after a stop or a FIFO reset) -> acquisition will resume at the next start-of-second
2024-06-05-12h44m10-UTC>INFO...-[TolmFrameBuilder::FrontEnd] source Sc_WI (64:v05) start acquisition aligned with the start-of-second
2024-06-05-12h44m10-UTC>ERROR..-[TfbSource::StoreData] producer Sc_WI channel Sc_WI_MIR_COIL_FLAG: substitution of missing data is over frame bound (17687 extra value(s)) (61 times)
2024-06-05-12h44m10-UTC>ERROR..-[TfbSource::StoreData] producer Sc_WI: overflow at GPS 1401626668.399913980 (received 3511 / expected 2000) (92171 times)

It seems this issue also caused a spike in the latency of the low-latency data sent out (attached plot).

 

 

Images attached to this comment
Search Help
×

Warning

Error

The present report has been modified outside this window. Please check for its integrity in the main page.

Refreshing this page will move this report into drafts.

×