Today the DaqBox 169 was replaced with the DaqBox 126 with the following mezzanines:
- Slot0: mezzanine ADC +/-10V nbr 84
- Slot1: mezzanine ADC +/-10V nbr 188
- Slot2: mezzanine ADC +/-10V nbr 252
- Slot3: mezzanine ADC +/-10V nbr 262
The DaqBox 169 was not working anymore since yesterday. The DaqBox was showing abnormal functioning since March 21.
https://logbook.virgo-gw.eu/virgo/?r=63851
This DBox destruction is explained by mice (or other animals...) which defecated on the DBox.
The DBox 126 was reconfigured at 9h44m40 UTC.
2024-04-09-09h44m40-UTC info letendre 'Reload config' sent to SWEB_dbox_rack