Reports 1-1 of 1 Clear search Modify search
AdV-INJ (General opto-mechanical layout, common parts construction, Installation and pre-commissioning)
derossi, melo, gosselin - 21:21 Wednesday 03 April 2024 (63830) Print this report
INJ noise hunting shift - RFC alignment and SBE EIB noise injections in LN3

RFC alignment in LN3

We moved the setpoints of the piezo from around 17h45 UTC to 18h10. We improved the alignment as shown in fig.1

(We also updated the thresholds in the DMS).

 

SBE EIB noise injections in LN3 (sine @ 0.5Hz)

DOF gps start UTC duration amplitude pp
tx 18:22:45 3 min 10 urad
ty 18:26:50 3 min 10 urad
tz 18:31:10 3 min 10 urad
x 18:34:40 3 min 10 um
y 18:38:08 3 min 10 um
z 18:41:39 3 min 10 um

Analysis of the noise injections will follow.

 

Images attached to this report
Comments to this report:
gosselin, derossi - 11:05 Thursday 04 April 2024 (63837) Print this report

We checked some signals of interest after the realignment of the RFC and could not see any clear improvment neither in LN3 (figure1) nor in INJ stand alone (figure 2).

Images attached to this comment
gosselin - 16:09 Thursday 04 April 2024 (63840) Print this report

To be noted that we managed to improve the alignment only using the PZT mounted on M19.
The PZT mounted on M20 had a strange behavior (red circle on figure attached). We were doing steps of 5V that were slightly changing the transmission and but then this transmission was going back to its original value by its own. Nothing was visible on the QPD.

Images attached to this comment
Search Help
×