The relock of today has been spent on several topics:
SSFS / IB alignment coupling
The ITF was unlocking at CARM 0 engaging SSFS. The plot is visible in Figure 1. There were some disturbances at 6Hz visible on SSFS (no loop oscillation) and bench control siguals (especially IB tx).
The reason could be a not optimal working of IB AA.
(The work has been interrupted by a failure of INJ/PSL occurred. INJ on-call has been called, see dedicated entry. BPC correction is high (UH corr).)
This kind of coupling between the SSFS and the INJ AA loop was observed in the past and was killed by setting offset on the QPD centering which minimized the coupling of the SSFS line on the QPDs.
The measurement are:
FF H 1362049034 : optimal wp is -0.35, see figure 5. (this is particularly big)
FF V 1362050783 : optimal wp is 0.157 see figure 6
NF H 1362052369 : optimal wp is -0.02
NF V 1362052982 : optima wp is -0.08
these have been updated in ISYS_Acl.
This action has solved the mis-behavior of SSFS/IB.
B1p shape @ DRMI
An other issue is that It is visible aslo in CITF that the DF shows a misalignment mode in ty. see figure 2
I've tried to align by hand to check if this was a problem of the BS AA loop but I could only increase the fringe without changing the shape of the mode.
The Figure 3 and 4 are the B1p Camera with the same gain.
We have talked to Diana.
Claudia has moved the ty of CH+DAS of NI. The B1p Camera shape @ DRMI did not change shape after Claudia's work.
SRCL set @ ~12 during the lock acquisiton
Then I found an issue (that started few days ago) figure 7. It was not possible to discharge the filters (I asked Diego and he has removed and put back the controller).
SRCL SET issue has been solved.
After having solved all these issues was possible to lock at CARM 0 1f
We locked then at 1f with the target of having gentle unlock after 1 h.
Figure 9 shows the trend of the last lock.