Reports 1-1 of 1 Clear search Modify search
AdV-DET (Local controls for all benches)
berni, bonnand, masserot - 10:13 Tuesday 07 February 2023 (58741) Print this report
Check of Coil driver box at WEB

This morning, Francesco went to WE Building to check the cabling on the Coil Driver box of SWEB.

All the cables looks properly plugged.

Francesco also checked the plugging of the Sub-D25 on the bottom flange of the mini-tower, plugging OK.

 

The Coil Driver box has been switch off around 8:06:50 for about 30 seconds or more.

The signals looks the same after switch OFF/ON.

 

The DAC that sends the current to the COIL has been reconfigure, also here no effect visible.

2023-02-07-08h10m31-UTC    info bonnand      process:SWEB_LC stopped
2023-02-07-08h10m43-UTC    info masserot     Reconfigure SWEB_DAC_LC_LVDT_out in SWEB_dbox_rack

 

The DaqBox 43 connected to the coil driver box (SWEB_ADC_LC_LVDT_out, SWEB_DAC_LC_LVDT_out, SWEB_ADC_MONI0, WEB_MezzCam) has been switch OFF at 09:13:48 for about 45 seconds.

And then it has been reconfigured :

2023-02-07-08h14m36-UTC    info masserot     Reconfigure WEB_MezzCAM in SWEB_dbox_rack
2023-02-07-08h14m49-UTC    info masserot     Reconfigure SWEB_ADC_MONI0 in SWEB_dbox_rack
2023-02-07-08h14m59-UTC    info masserot     Reconfigure SWEB_DBOX_LC in SWEB_dbox_rack
2023-02-07-08h15m10-UTC    info masserot     Reconfigure SWEB_DBOX_LC in SWEB_dbox_rack

Nothing changed.

 

Then we reconfigured the DAC that sends the modulation line inside the electronic container:

2023-02-07-08h18m39-UTC    info masserot     process:SWEB_LC stopped
2023-02-07-08h18m51-UTC    info masserot     Reconfigure SWEB_DAC_LC_LVDT_in in SWEB_dbox_bench

No effect on the read-out observed.

 

Then we stopped sending the line to the primary coil at:

2023-02-07-08h23m27-UTC    info masserot     SWEB_LC saved - masserot: set the weigth for th lines at 0 (rev. 232506)
2023-02-07-08h23m28-UTC    info masserot     process:SWEB_LC started

We reconfigured again the DAC that sends the current to control the bench :

2023-02-07-08h25m54-UTC    info masserot     process:SWEB_LC stopped
2023-02-07-08h26m14-UTC    info masserot     Reconfigure SWEB_DAC_LC_LVDT_out in SWEB_dbox_rack
2023-02-07-08h26m20-UTC    info masserot     process:SWEB_LC started

Put back the modulation line :

2023-02-07-08h32m47-UTC    info masserot     SWEB_LC saved - masserot: set the weigth for th lines at 1 (rev. 232516)
2023-02-07-08h32m54-UTC    info masserot     'Acl:Reload config' sent to SWEB_LC

Switch OFF and ON the modulation line again :

2023-02-07-08h38m23-UTC    info masserot     SWEB_LC saved - masserot: set the weigth for th lines at 0 (rev. 232517)
2023-02-07-08h38m30-UTC    info masserot     'Acl:Reload config' sent to SWEB_LC
2023-02-07-08h40m41-UTC    info masserot     SWEB_LC saved - masserot: set the weigth for th lines at 1 (rev. 232518)
2023-02-07-08h40m45-UTC    info masserot     'Acl:Reload config' sent to SWEB_LC

 

All the checks did not change anything in the SWEB_LC_LVDT_B/F/L/R_H/V_out_raw signals (read-out signals of secondary coils) that show a peak at around 7.8 kHz this morning, see plot attached.

 