Comment to Matching of north arm -- estimation of north arm CP focal length (55886)

To have the estimate of the North CP cold lens, I made a transient simulation of the evolution of the CH lens (see figure 1).

After 15 minutes, the focal length is about 31 km, already almost equal to the steady state value and half of what was estimated from the CP map.