Operator Report - Morning shift

The first part of the shift was dedicated to the recovery of the SatServer. Thanks to the intervention of Carbognani we identified the issue as the missing gnames of ScBS: Boschi was able to restore the standard condition at 8:43 UTC and, after SatServer was restarted, the ISC activity could start.
The rest of the shift was dedicated to the ISC activity, carried out by Valentini with the remote support of Mantovani and Casanueva. The activity proceeded without any further issues.
Activity still in progress.

Oncall events

SUSP
(13-09-2021 07:30 - 13-09-2021 08:40) From remote
Status: Ended
Description: The SatServer was not able to work correctly due to the missing data of ScBS. This configuration prevented access to the various interfaces and change of states of the various SUS Metatron Nodes.
Actions undertaken: I contacted the SUSP Oncall ( Boschi ) that, from remote, was able to re-establish the connection with ScBS.