Upon arrival I found ITF in Science Mode with BNS Range ~45 Mpc.
It unlocked at 01:53 UTC due to a misalignment of PR (plot1). ITF relocked at first attempt at 02:29 UTC. BNS Range ~45 Mpc.
It unlocked again at 02:35 UTC (plot2) and relocked agaim at first attempt at 02:55 UTC. BNS Range ~45 Mpc.

At 00:54 and at 04:10 UTC drops in the BNS Range from 45 to 10 Mpc.

Guard Tour (UTC)
22:28  - 23:00
00:30  - 01:04
02:30  - 03:00
04:00  - 04:30

DAQ
At 01:54 UTC eeload config of FbsDet under request of Masserot.

Images attached to this report
Comments to this report:
ruggi - 8:15 Wednesday 11 September 2019 (46886) Print this report

Both the locklosses are preceded by a NI board failure.