During the afternoon shift we continued the recovery of the ITF:
- we tuned the last demodulation phase, the B5_QD2 one for the PR/BS automatic alignment loops;
 - no other major tuning was needed but the gain of the SSFS for the most part of the lock acquisition;
 - the 100 Hz line was very high tonight, especially so on DARM and PRCL; on DARM it gets quite reduced when moving from RF to DC sensing; since the DARM spectrum was quite low at this point, we reduced the UGF line amplitude of a factor 6;
 - once in LOW_NOISE_3, after the BS loop switches to full bandwidth, we engaged by hand the new filter for MICH (again, removing the notches for, probably, filter allocation reasons);
 - that made both the sensitivity and the range get better, especially at low frequency, resulting in a BNS Range floating around 35 Mpc, reaching 36 Mpc for a very brief time!
 - a stretch of clean data is from 19:16:00 UTC to 19:39:00 UTC;
 - after this period of time, we had a sudden drop in the sensitivity, with the bucket often rising; it may be interesting to look for correlations during this phase;
 - however, the ITF and/or the IMC are a bit shaky after an unlock (natural or induced) and the first trial usually fails at CARM2MC;
 - at the end we played a bit with the setpoint of the BS_TY loop, with the usual change in the CMRF but no effect on the sensitivity;
 - we did a few more trials to engage the full MICH filter, increasing both its order and the one of the LSC_NONE 'placeholder', without success; in the attached log there is one attempt, where one concerning thing is the "15/12" relative to the order, where without the 3 notches the log says "12/12";
 - a very weird unlock, triggered by the 100 Hz on DARM but with lots of lines and glitches on the spectrum, occurred around 21:12:11 UTC.
 
We left the ITF with target state LOW_NOISE_3, with the old MICH filter and in the AUTORELOCK mode.
The last working configuration for Metatron was checked in as revision r73511.