Reports 1-1 of 1 Clear search Modify search
TCS (TCS)
swinkels, blom - 22:28 Monday 16 November 2009 (25648) Print this report
Small changes in Alp_TCS
To prepare for the future implementation of servos to stabilize the etalons, we added some code to Alp_TCS that reads the temperatures calculated by Michele's line monitor from file and stores them in the DAQ, see fig 1. The new channel names are Alp_TCS_NI_Mirror_Temp and Alp_TCS_WI_Mirror_Temp. If the last calculation is too old (when the ITF is not locked), Alp_TCS_Mirror_Temp_Valid is set to zero.

We also corrected a bug in the temperature stabilization loop of the WI, which was already corrected for the NI in October. The new set-point for the chiller was calculated as New_Chiller_Setpoint = Old_Chiller_Temperature + correction, while it should be New_Chiller_Setpoint = Old_Chiller_SetPoint + correction. Also the gain of the loop was increased, like was done for the NI. The accuracy of this loop is now similar the one of the NI, see fig 2.
Images attached to this report
Search Help
×

Warning

×