Online Data Analysis (MBTA)F. Robinet - 10:51 Wednesday 14 October 2009 (25212)
Print this reportHourly Omega ScansSince the high SNR events are now pretty rare (for how long?), I have lower the SNR threshold to start an hourly scan :
MBTA 12 → 10
Omega 18 → 15
Unrelated logbook remark : in the 'Online Data Analysis' section of the logbook, there 4 choices of tasks : 'DQ', 'KW', 'MBTA' and 'WDF'. Where is 'Omega' ?
Comments to this report:
F. Robinet - 14:20 Wednesday 14 October 2009 (25218)
Print this reportAfter a second thought, I have further lower the omega scan threshold to snr=10 for omega triggers. This guaranties at least a scan every hour.
High SNR glitches seem to have disappear, the scientist on shift might get bored with no scan to look at ;-)