Reports 1-1 of 1 Clear search Modify search
Interferometer_sensitivity_studies (General)
Vajente - 12:15 Monday 10 March 2008 (20082) Print this report
More on glitches
In addition to entries
Glitch
Glitches

The modes that are excited by the glitches are:
3917.5 Hz
5584.0 Hz
9831, 9850, 9889 Hz

According to Michele, the 5584 Hz line is an internal mode of the WI mirror.
There is no clear and visible effect on the violin modes around 300 Hz.
Nothing is visible on the RM coil current monitors.

In conclusion it seems that the glitches are caused by some event happening at the WI suspension, likely at the level of the mirror itself.
Images attached to this report
Comments to this report:
swinkels - 13:16 Monday 10 March 2008 (20083) Print this report
If true, could this be some sort of relaxation process in the
recently glued magnets? In particular at the WI, the spacers were reattached with water-glass. We might have to wait some time until the process has settled in a final state.
Search Help
×

Warning

Error

The present report has been modified outside this window. Please check for its integrity in the main page.

Refreshing this page will move this report into drafts.

×