Detector Operation (Automation)swinkels - 0:03 Friday 08 May 2009 (22850)
Print this reportCannot restart AlpGcWhile trying to upload a new version of alpha, I could not restart AlpGc. I suspect some stupid typo, but I cannot find anything and the error message is also not really helpful (return code -1). I restored config files from the daily backup files, but this did not help either. To be fixed first thing tomorrow morning, we cannot relock without AlpGc.
Comments to this report:
masserot - 0:46 Friday 08 May 2009 (22851)
Print this reportHere the report for an rsh on olserver1:
clnt_call: RPC: Unable to receive; errno = No route to host
YPBINDPROC_DOMAIN: Domain not bound
do_ypcall: clnt_call: RPC: Unable to receive; errno = No route to host
YPBINDPROC_DOMAIN: Domain not bound
do_ypcall: clnt_call: RPC: Unable to receive; errno = No route to host
YPBINDPROC_DOMAIN: Domain not bound
Password:
do_ypcall: clnt_call: RPC: Unable to receive; errno = No route to host
YPBINDPROC_DOMAIN: Domain not bound
do_ypcall: clnt_call: RPC: Unable to receive; errno = No route to host
YPBINDPROC_DOMAIN: Domain not bound
do_ypcall: clnt_call: RPC: Unable to receive; errno = No route to host
YPBINDPROC_DOMAIN: Domain not bound
Password:
do_ypcall: clnt_call: RPC: Unable to receive; errno = No route to host
YPBINDPROC_DOMAIN: Domain not bound
do_ypcall: clnt_call: RPC: Unable to receive; errno = No route to host
YPBINDPROC_DOMAIN: Domain not bound
Login incorrect
login: virgorun
do_ypcall: clnt_call: RPC: Unable to receive; errno = No route to host
YPBINDPROC_DOMAIN: Domain not bound
do_ypcall: clnt_call: RPC: Unable to receive; errno = No route to host
YPBINDPROC_DOMAIN: Domain not bound
Password:
do_ypcall: clnt_call: RPC: Unable to receive; errno = No route to host
YPBINDPROC_DOMAIN: Domain not bound
do_ypcall: clnt_call: RPC: Unable to receive; errno = No route to host
YPBINDPROC_DOMAIN: Domain not bound
Login incorrect
login: rlogin: connection closed.
It seems that:
* all the olservers from olserver1 to olserver8 are unreachable by ssh and rsh.
* The olservers from olserver9 to olserver14 are reachable by ssh and rsh
* the olsevers from olserver15 to the olserver16 are unreachable by ssh and rsh
Comments to this report:
dibiase - 9:49 Friday 08 May 2009 (22852)
Print this reportYesterday night has crashed YP1 and all new olservers than haven't redundant Y2 server in /etc/yp.conf were unable to be accessed in rsh or ssh mode. I add y2 as redundat server in their yp configuration file and restart yp service on new olservers.