AdV-ISC (Parametric instabilities)
bogaert - 14:00 Wednesday 26 February 2020 (48566) Print this report
Comment to 155kHz line on B7 PD1 (48565)
And the signal in B8 PD1 grows the same way as B8 PD2 (with a different scale).
AdV-ISC (Parametric instabilities)
Allocca, Bogaert - 12:28 Wednesday 26 February 2020 (48565) Print this report
155kHz line on B7 PD1

From a better analysis of the photodiodes signals, the 155kHz line seem to be visible on B7 PD1 (figure 1), while no signal is visible on PD2. The same happens also for B8 PD1. This is quite surprising because the shutter in front of PD1 should be closed in dark fringe. Further investigation are needed to better clarify why the signal is not visible on B7_PD2.

Images attached to this report
Comments to this report:
bogaert - 14:00 Wednesday 26 February 2020 (48566) Print this report
And the signal in B8 PD1 grows the same way as B8 PD2 (with a different scale).
AdV-ISC (Parametric instabilities)
Allocca - 12:33 Tuesday 11 February 2020 (48421) Print this report
Comment to 155kHz line moving with NI temperature (48374)

After the test of increasing the temperature of the NI using the heating belts, we still had some doubt that the line giving rise to the instability on Jan 7th and 8th was not the same as we observed to be moving during the test.

For this reason, a further analysis was performed: the frequency of the 155kHz line was followed during the unlocks taking place on Jan 7th and 8th (see figure 1). As the temperature of the four test masses is not constant over the two analyzed days, the frequency is also expected to change linearly with the temperature.

In figure 2, the frequency shift of the line is shown as a function of the four test masses temperatures. The behaviour is linear only for the NI and WI, pointing again to one of the INPUT. 

Finally, from the HB test, we observed that not only the NI, but also the NE test mass temperature was varying by about the same amount, so I superimposed the data from the instability events to the data from the heating belt experiment. The results are shown in figure 3. The data follow the same trend as the NI, and we also find the same frequency for the same temperature value. From these data we can say that the line giving rise to the instability belongs to the NI test mass. 

Images attached to this comment
AdV-ISC (Parametric instabilities)
Allocca - 11:18 Friday 07 February 2020 (48379) Print this report
Further analysis of the 155kHz instability

I gave a further look to the unlocks of Jan 7th, in particular to the once happening before LN3, which are slower and allow to appreciate the high order mode rising up on B1p camera.

The shape of the high order mode appearing right before the unlock evolves in time, passing from an HG01 on Jan 7th to an HG10 on Jan 8th (see figures 1 to 3). This latter is visible only in the last unlock before the normal operation of the interferometer is recovered.

Comparing the frequencies of the 155kHz line in the first and last case, they differ by almost 1Hz (figure 4). The temperature variation of the NI test mass is about 0.1K (figure 5), which would give a frequency shift of ≈1.7Hz, so it's difficult to understand if the line which gives rise to the two event is the same and is shifted by the temperature or maybe it's another mode which gets excited. 

Looking at the B7 and B8 signals sampled at 400MHz, it seems that on the event of Jan 8th a small peak at around 150kHz is also visible on B7, but it could also be some random noise. Still to understand why no clear signal is visible on B7.

Images attached to this report
AdV-ISC (Parametric instabilities)
Allocca - 14:12 Thursday 06 February 2020 (48374) Print this report
155kHz line moving with NI temperature

Last night, the setpoint of the NI heating belt has been changed by 0.3 K in order to change the temperature of NI test mass only. This test had the aim to verify whether the 155.408kHz peak belongs to the NI. If yes, the frequency of this line should move by a known amount, as computed below.

In figure 1, the temperature variation for the four test masses is shown for the analyzed period (gps1 = 5/2/20 22h00 UTC --> gps2 = 6/2/20 10h38 UTC). Moreover, also the correction given to the two heating belts is plotted. What was not expected is that both the temperature of NI and NE changes by approximately the same amount, which is, respectively:

deltaT_NI = 0.3K

deltaT_NE = 0.27K

A much smaller temperature variation is seen instead on the West test masses, also thanks to the etalon loop acting on the WI tower and keeping the WI temperature almost constant. 

Taking into account the rate of frequency change reported in 42370, using the temperature variation for NI and NE, it is possible to compute the expected frequency change for the 155.4kHz line:

0.67Hz/K * (155.4kHz/7.8kHz) * deltaT_NE ≈ 3.6Hz

0.87Hz/K * (155.4kHz/7.8kHz) * deltaT_NI ≈ 5.2Hz

In the attached movie, a zoom around the frequency of interest of the B1 spectrum is shown. A plot is taken every 3500 seconds, and it is possible to follow the evolution in frequency of the 155kHz line.

In figure 2, the two superimposed plots correspond to gps1 and gps2, respectively.

The measured frequency shift is ≈ 4.8Hz, which is compatible with the value expected for the NI test mass.

Images attached to this report
Non-image files attached to this report
Comments to this report:
Allocca - 12:33 Tuesday 11 February 2020 (48421) Print this report

After the test of increasing the temperature of the NI using the heating belts, we still had some doubt that the line giving rise to the instability on Jan 7th and 8th was not the same as we observed to be moving during the test.

For this reason, a further analysis was performed: the frequency of the 155kHz line was followed during the unlocks taking place on Jan 7th and 8th (see figure 1). As the temperature of the four test masses is not constant over the two analyzed days, the frequency is also expected to change linearly with the temperature.

In figure 2, the frequency shift of the line is shown as a function of the four test masses temperatures. The behaviour is linear only for the NI and WI, pointing again to one of the INPUT. 

Finally, from the HB test, we observed that not only the NI, but also the NE test mass temperature was varying by about the same amount, so I superimposed the data from the instability events to the data from the heating belt experiment. The results are shown in figure 3. The data follow the same trend as the NI, and we also find the same frequency for the same temperature value. From these data we can say that the line giving rise to the instability belongs to the NI test mass. 

Images attached to this comment
AdV-ISC (Parametric instabilities)
michimura - 18:38 Wednesday 08 August 2018 (42370) Print this report
Comment to Mirror mode identification with temp change (41794)

Using the ring heater temperatures and line frequencies from the line tracker, the arm mirror modes upto 15kHz are identified.
For modes with higher frequencies, it was hard to identify from this method.

Summary:
[Drum modes around 7.807kHz (time series plot, temperature vs line frequency plot, B1 spectrum)]
PAY_DRUM1_FREQ: NI 0.878 Hz/K
PAY_DRUM2_FREQ: WI 0.871 Hz/K
PAY_DRUM3_FREQ: currently no line in the band
PAY_DRUM4_FREQ: lower frequency is from WE 0.882 Hz/K, upper frequency from NE 0.676 Hz/K?

[Modes around 10.107kHz (time series plot, temperature vs line frequency plot, B1 spectrum)]
PAY_10kHz1_FREQ: NI 1.074 Hz/K
PAY_10kHz2_FREQ: WI 1.083 Hz/K
PAY_10kHz3_FREQ: currently no line in the band
PAY_10kHz4_FREQ: lower frequency is from WE 1.057 Hz/K, upper frequency from NE 0.842 Hz/K?

[Modes around 15.007kHz (time series plot, temperature vs line frequency plot, B1 spectrum)]
PAY_15kHz1_FREQ: NI? 1.584 Hz/K?
PAY_15kHz2_FREQ: NE? 1.109 Hz/K?
PAY_15kHz3_FREQ: WE 1.720 Hz/K
PAY_15kHz4_FREQ: WI? 1.357 Hz/K?
PAY_15kHz5_FREQ: unclear

[Modes around 26.2kHz (time series plot, temperature vs line frequency plot, B1 spectrum)]
PAY_26kHz1_FREQ: WE? 2.033 Hz/K
PAY_26kHz2_FREQ: unclear
PAY_26kHz3_FREQ: WE? 2.021 Hz/K

[Modes around 9.67-8kHz (time series plot 1-4 5-8, temperature vs line frequency plot 1-4 5-8, B1 spectrum)]
PAY_9pt6kHz1_FREQ: WI 0.849 Hz/K
PAY_9pt6kHz2_FREQ: NI 0.840 Hz/K
PAY_9pt6kHz3_FREQ: WI (noisy)
PAY_9pt6kHz4_FREQ: NI (noisy)
PAY_9pt6kHz5_FREQ: NE 0.629 Hz/K? (line moves to 9pt6kHz6)
PAY_9pt6kHz6_FREQ: lower frequency from NE 0.778 Hz/K?, upper frequency from WE 0.831 Hz/K
PAY_9pt6kHz7_FREQ: NE, but basically no line in the band (line moves to 9pt6kHz8)
PAY_9pt6kHz8_FREQ: lower frequency from NE, upper frequency from WE (noisy)

[Modes around 39.2-3kHz (time series plot 1-4 5-8, temperature vs line frequency plot 1-4 5-8, B1 spectrum)]
PAY_39kHz1_FREQ: unclear
PAY_39kHz2_FREQ: unclear
PAY_39kHz3_FREQ: WE 3.635 Hz/K?
PAY_39kHz4_FREQ: unclear
PAY_39kHz5_FREQ: currently no line in the band
PAY_39kHz6_FREQ: WI 3.208 Hz/K
PAY_39kHz7_FREQ: WE 3.291 Hz/K
PAY_39kHz8_FREQ: WI? 3.742 Hz/K

[Modes around 43.9-44.1kHz (time series plot, temperature vs line frequency plot, B1 spectrum)]
PAY_44kHz1_FREQ: unclear
PAY_44kHz2_FREQ: unclear
PAY_44kHz3_FREQ: WI? 3.633 Hz/K?
PAY_44kHz4_FREQ: unclear
PAY_44kHz5_FREQ: currently no line in the band
PAY_44kHz6_FREQ: unclear

Dots in different colors indicate data from different locks.


Method:
I did a similar analysis done a year ago by Bas (logbook #39039), using 4 days of data during the commissioning run in Aug 2-5. Data in LOW_NOISE_3 is used.

1. Make temperature vs line frequency plots using ring heater temperatures (INF_TCS_NI_RH_TE, INF_TCS_WI_RH_TE, ENV_TCS_NE_RH_TE, ENV_TCS_WE_RH_TE) and line tracker frequency outputs (PAY_{mode}_FREQ).

2. Calculated correlation coefficients and linear fitted to get the temperature dependence. Used these information to identify the mirror.

3. For line tracker frequency output channels tracking two modes, I splitted the data into two using moving average using the time window of 3000 seconds. Lower frequency output is labeled with the suffix _lower, and upper frequency output is labeled with the suffix _upper.


Result:
[Drum modes around 7.807kHz]
From correlation coefficients, we can clearly see that DRUM1 is from NI and DRUM2 is from WI.
DRUM3 is now tracking nothing, and DRUM4 is tracking two modes. Lower frequency of DRUM4 can be identified to be WE from the correlation coefficient.
Upper frequency of DRUM4 is therefore NE.
These results are consistent with previous studies (logbook #41935, #41794 (this figure) and VIR-0505A-18).
The temperature dependance of drum mode frequencies is ~0.88 Hz/K, which is consistent with previous studies (logbook #39039, #41798).

[Modes around 10.107kHz]
Modes can be identified similarly with drum modes.
These results are consistent with previous studies  (logbook #41794 (this figure) and VIR-0505A-18).
The temperature dependance of mode frequencies is ~1.07 Hz/K.

[Modes around 15.007kHz]
For these modes, some of the lines moved from one channel to different channel, so I only used the first half (~ 2 days) of the data.
15kHz3 can be clearly identified to be WE and is consistent with logbook #41794 (this figure).
Others are quite unclear, but considering the combination of high correlation coefficients and temperature dependance close to 1.7 Hz/K obtained from WE, 15kHz1, 15kHz2 and 15kHz4 are likely to be from NI, NE and WI respectively.

[Modes around 26.2kHz]
For these modes, the line at 26kHz2 moved out from the frequency region, so I only used the first half (~ 2 days) of the data.
Both 26kHz1 and 26kHz3 has high correlation with WE temperature, as already found in logbook #41794 (this figure).
They might not be from mirror modes, but something from WE.

[Modes around 9.6kHz]
These modes are tricky (they were also quiet during the weekend).
From study in logbook #41794 (this figure), we can see that 9pt6kHz6 and 9pt6kHz8 are from WE. There are 4 groups but they do not correspond to 4 mirrors and groups are mixed.
From correlation coefficients, we can clearly see that 9pt6kHz1 is from WI and 9pt6kHz2 is from NI.
Therefore, we can guess that 9pt6kHz3 and 9pt6kHz4 are also from WI and NI, respectively, although these channels are noisy due to small amplitude during the weekend. For fitting the data of these channels, I only used the data which has not too large fluctuation from the trend we can see by our eye (data used is indicated with black dots).
The rest is 9pt6kHz5 and 9pt6kHz7 and they are from NE. 9pt6kHz7 is currently out of band and NE mode is actually tracked by 9pt6kHz8. Also, NE line in 9pt6kHz5 moved to 9pt6kHz6 during the weekend.
We can also confirm that all the temperature dependances of mode frequencies are ~0.84 Hz/K.

[Modes around 39.2-3kHz]
These modes were quiet and unclear.
From study in logbook #41794 (this figure and this figure), we can see that 39kHz3 and 39kHz7 are from WE, and correlation coefficients support this.
We can also see that 39kHz6 and 39kHz8 have high coherence with WI temperature and similar temperature dependance (~3.2-3.7 Hz/K).
For 39kHz1, it was noisy and unclear.
For 29kHz2, correlation coefficients are similar for each mirror and unclear.
For 39kHz4, the line moved away from the band and we don't have much data.
If you look at the B1 spectrum, we see peak at 39306 Hz, which is not tracked by the line tracker. No line in 39kHz5 band.
We might have to check these modes and line tracker bands again when these modes are excited.

[Modes around 43.9-44.1kHz]
For these modes, no plot is in logbook #41794. So, I made one here.
As you can see, no peaks in this line tracker frequency band moved during large temperature change in WE in June 10.
44kHz3 has high correlation with WI temperature, so it might be from WI, but others are unclear.
May be we should look into these modes again.

Images attached to this comment
AdV-ISC (Parametric instabilities)
hardwick, michimura - 16:49 Wednesday 13 June 2018 (41815) Print this report
Comment to Mirror mode identification with temp change (41794)

Beamsplitter drum (~1875 Hz) and butterfly (~1256 Hz) now tracked as well as PAY_BS_DRUM/BUTTERFLY_AMPL/FREQ

AdV-ISC (Parametric instabilities)
michimura, hardwick - 17:14 Tuesday 12 June 2018 (41807) Print this report
Comment to Mirror mode identification with temp change (41794)

We've updated Bas's drum mode tracker to the new frequencies (which shifted with the monolithic suspension install). We've also added 9.6 kHz modes.

Channels are:

  • V1:PAY_DRUM#_AMPL and V1:PAY_DRUM#_FREQ where # = 1,2,3, or 4 in order of increasing frequency.
  • V1:PAY_9pt6kHz#_AMPL and FREQ, where # = 1 - 8

These channels are available on MoniUsers starting 1212850711 (for Drum; 9pt6 came a few minutes later), at which time old channels (TCS_ETALON_XX_DRUM# and _WE_DRUM#) became unavailable.

Code available at /virgoDev/Automation/PyALP/PySpectral/algo.py.

Images attached to this comment
AdV-ISC (Parametric instabilities)
hardwick - 16:33 Tuesday 12 June 2018 (41805) Print this report
Comment to Mirror mode identification with temp change (41794)

Note (from Mwas on duplicate entry 41799): 'The line at 12.8kHz is not a mirror mode but the OMC1 length PZT dither at 12831.3Hz to get OMC lock signal. There should also be a line at 15569Hz which is the OMC2 length PZT dither.'

I confirm I also found the 15.5 kHz mode. Thank you!

AdV-ISC (Parametric instabilities)
mwas - 16:12 Tuesday 12 June 2018 (41803) Print this report
Comment to Mirror mode identification with temp change (41799)
The line at 12.8kHz is not a mirror mode but the OMC1 length PZT dither at 12831.3Hz to get OMC lock signal. There should also be a line at 15569Hz which is the OMC2 length PZT dither.
AdV-ISC (Parametric instabilities)
puppo - 15:44 Tuesday 12 June 2018 (41800) Print this report
Comment to Mirror mode identification with temp change (41794)
The mode at 12.8kHz is the first bulk mode that could give a non negligible instability effect, however the simulations output indicate that it is still below 1 for mirror quality factors of 1e7.

See https://tds.virgo-gw.eu/ql/?c=13057

A first estimations of the Q's of this kind of mode indicate that for the WE mirror we are below 1e7 (from thermal peak).
Further investigation on the data are still ongoing.




AdV-ISC (Parametric instabilities)
hardwick - 15:32 Tuesday 12 June 2018 (41799) Print this report
Mirror mode identification with temp change

I've used the large temperature change over the past weekend to identify WETM mirror modes.

- - - - - -

Eigenfrequencies of the test masses are proportional to square root of Young's modulus: f ~ E1/2, where E := Young's modulus. The Young's modulus for fused silica has some temperature dependence ( measured to be (dE/dT)/E = 1.52e-4 / K ); as temperature increases, Young's modulus increases, so the mode frequency increases over a lock stretch with self heating, ring heaters, or with a strong ambient temperature increase.

With the accidental temperature change test at WE over the weekend (starting Sunday morning ~1:00 UTC,  41771), we are thus able to identify modes of of the West End mirror by their frequency shifts. The first attachment shows the rise of the room temperature on the top and the subsequent rise of the ring heater temperature sensor on the bottom, the latter lagging by ~6.7 hours.

In the rest of the attachments, I zoom into relevant frequency bands (specified in name of attachment) of the high rate V1:SDB2_B1_PD2_Audio_100k channel. We had two several hour locks on Sunday during the WE temperature change, the first lock starting shortly before the temperature change began. In the plots, purple is taken at the beginning of the first lock and blue is taken at end of second lock, at which point room temp had increased by 1 C and RH temp had increased by 0.2 C. I have tried to highlight bands expected to have the highest parametric gain according to Dan Hoak's document VIR-0525A-16, but some bands I couldn't identify.

Of note:

  • 7.8 kHz (Drum modes): In 41732, Swinkels noted the missing drum mode; as he suspected, we have two test masses with nominally same drum mode frequency ~7809 Hz. WE mirror drum mode was revealed with temp change.
  • 9.6 kHz: It had been thought that there was a mode group around 9670 Hz and 9685 Hz, but this indicates that the two mode groups are mixed.
  • 10.1 kHz: again, two masses with almost same nominal mode frequency
  • 12.8 kHz: what looks like a test mass mode with rather high amplitude, high PI gain? This would interact with LG02.

- - - - - -

Note: There are upcoming ring heater tests of the end mirrors which will further help with mode identification since the ring heaters will be stepped one at a time. keywords: parametric instability, PI, mirror modes, temperature change

Images attached to this report
Comments to this report:
mwas - 16:12 Tuesday 12 June 2018 (41803) Print this report
The line at 12.8kHz is not a mirror mode but the OMC1 length PZT dither at 12831.3Hz to get OMC lock signal. There should also be a line at 15569Hz which is the OMC2 length PZT dither.
AdV-ISC (Parametric instabilities)
michimura - 15:20 Tuesday 12 June 2018 (41798) Print this report
Comment to Mirror mode identification with temp change (41794)

Bas pointed out that drum mode tracker is not useful anymore because of the frequency shift (logbook #41732). But the temperature change in WE (logbook #41771) shifted the drum mode frequency to higher frequencies, and TCS_ETALON_XX_DRUM2_FREQ luckily could track this shift.

I did a similar analysis done a year ago (logbook #39039) to see the temperature dependence. Figure 1 is the plot comparing drum mode frequencies with NI,WI,NE,WE ring heater temperatures. You can see that TCS_ETALON_XX_DRUM2_FREQ follows ENV_TCS_WE_RH_TE. The temperature dependence is 0.85 Hz/K, which is consistent with a measurement done a year ago (logbook #39039). Other drum mode trackers are currently useless. We have to change the code to account for the frequency shift after the monolithic suspension installation.

Figure 2 is the raw time series data used in this analysis. I only used the data when the interferometer is "locked" (LSC_B7_DC > 250).

Images attached to this comment
AdV-ISC (Parametric instabilities)
hardwick - 14:44 Tuesday 12 June 2018 (41794) Print this report
Mirror mode identification with temp change

I've used the large temperature change over the past weekend to identify WETM mirror modes. - - - - - - Eigenfrequencies of the test masses are proportional to square root of Young's modulus: f ~ E1/2, where E := Young's modulus. The Young's modulus for fused silica has some temperature dependence ( measured to be (dE/dT)/E = 1.52e-4 / K ); as temperature increases, Young's modulus increases, so the mode frequency increases over a lock stretch with self heating, ring heaters, or with a strong ambient temperature increase. With the accidental temperature change test at WE over the weekend (starting Sunday morning ~1:00 UTC, log 41771), we are thus able to identify modes of of the West End mirror by their frequency shifts. The first attachment shows the rise of the room temperature on the top and the subsequent rise of the ring heater temperature sensor on the bottom, the latter lagging by ~6.7 hours. In the rest of the attachments, I zoom into relevant frequency bands (specified in name of attachment) of the high rate V1:SDB2_B1_PD2_Audio_100k channel. We had two several hour locks on Sunday during the WE temperature change, the first lock starting shortly before the temperature change began. In the plots, purple is taken at the beginning of the first lock and blue is taken at end of second lock, at which point room temp had increased by 1 C and RH temp had increased by 0.2 C. I have tried to highlight bands expected to have the highest parametric gain according to Dan Hoak's document VIR-0525A-16, but some bands I couldn't identify. Of note: - 7.8 kHz (Drum modes): In 41732, Swinkels noted the missing drum mode; as he suspected, we have two test masses with nominally same drum mode frequency ~7809 Hz. WE mirror drum mode was revealed with temp change. - 9.6 kHz: It had been thought that there was a mode group around 9670 Hz and 9685 Hz, but this indicates that the two mode groups are mixed. - 10.1 kHz: again, two masses with almost same nominal mode frequency - 12.8 kHz: what looks like a test mass mode with rather high amplitude, high PI gain? This would interact with LG02. - - - - - - Note: There are upcoming ring heater tests of the end mirrors which will further help with mode identification since the ring heaters will be stepped one at a time. keywords: parametric instability, PI, mirror modes, temperature change

Images attached to this report
Comments to this report:
michimura - 15:20 Tuesday 12 June 2018 (41798) Print this report

Bas pointed out that drum mode tracker is not useful anymore because of the frequency shift (logbook #41732). But the temperature change in WE (logbook #41771) shifted the drum mode frequency to higher frequencies, and TCS_ETALON_XX_DRUM2_FREQ luckily could track this shift.

I did a similar analysis done a year ago (logbook #39039) to see the temperature dependence. Figure 1 is the plot comparing drum mode frequencies with NI,WI,NE,WE ring heater temperatures. You can see that TCS_ETALON_XX_DRUM2_FREQ follows ENV_TCS_WE_RH_TE. The temperature dependence is 0.85 Hz/K, which is consistent with a measurement done a year ago (logbook #39039). Other drum mode trackers are currently useless. We have to change the code to account for the frequency shift after the monolithic suspension installation.

Figure 2 is the raw time series data used in this analysis. I only used the data when the interferometer is "locked" (LSC_B7_DC > 250).

Images attached to this comment
puppo - 15:44 Tuesday 12 June 2018 (41800) Print this report
The mode at 12.8kHz is the first bulk mode that could give a non negligible instability effect, however the simulations output indicate that it is still below 1 for mirror quality factors of 1e7.

See https://tds.virgo-gw.eu/ql/?c=13057

A first estimations of the Q's of this kind of mode indicate that for the WE mirror we are below 1e7 (from thermal peak).
Further investigation on the data are still ongoing.




hardwick - 16:33 Tuesday 12 June 2018 (41805) Print this report

Note (from Mwas on duplicate entry 41799): 'The line at 12.8kHz is not a mirror mode but the OMC1 length PZT dither at 12831.3Hz to get OMC lock signal. There should also be a line at 15569Hz which is the OMC2 length PZT dither.'

I confirm I also found the 15.5 kHz mode. Thank you!

michimura, hardwick - 17:14 Tuesday 12 June 2018 (41807) Print this report

We've updated Bas's drum mode tracker to the new frequencies (which shifted with the monolithic suspension install). We've also added 9.6 kHz modes.

Channels are:

  • V1:PAY_DRUM#_AMPL and V1:PAY_DRUM#_FREQ where # = 1,2,3, or 4 in order of increasing frequency.
  • V1:PAY_9pt6kHz#_AMPL and FREQ, where # = 1 - 8

These channels are available on MoniUsers starting 1212850711 (for Drum; 9pt6 came a few minutes later), at which time old channels (TCS_ETALON_XX_DRUM# and _WE_DRUM#) became unavailable.

Code available at /virgoDev/Automation/PyALP/PySpectral/algo.py.

Images attached to this comment
hardwick, michimura - 16:49 Wednesday 13 June 2018 (41815) Print this report

Beamsplitter drum (~1875 Hz) and butterfly (~1256 Hz) now tracked as well as PAY_BS_DRUM/BUTTERFLY_AMPL/FREQ

michimura - 18:38 Wednesday 08 August 2018 (42370) Print this report

Using the ring heater temperatures and line frequencies from the line tracker, the arm mirror modes upto 15kHz are identified.
For modes with higher frequencies, it was hard to identify from this method.

Summary:
[Drum modes around 7.807kHz (time series plot, temperature vs line frequency plot, B1 spectrum)]
PAY_DRUM1_FREQ: NI 0.878 Hz/K
PAY_DRUM2_FREQ: WI 0.871 Hz/K
PAY_DRUM3_FREQ: currently no line in the band
PAY_DRUM4_FREQ: lower frequency is from WE 0.882 Hz/K, upper frequency from NE 0.676 Hz/K?

[Modes around 10.107kHz (time series plot, temperature vs line frequency plot, B1 spectrum)]
PAY_10kHz1_FREQ: NI 1.074 Hz/K
PAY_10kHz2_FREQ: WI 1.083 Hz/K
PAY_10kHz3_FREQ: currently no line in the band
PAY_10kHz4_FREQ: lower frequency is from WE 1.057 Hz/K, upper frequency from NE 0.842 Hz/K?

[Modes around 15.007kHz (time series plot, temperature vs line frequency plot, B1 spectrum)]
PAY_15kHz1_FREQ: NI? 1.584 Hz/K?
PAY_15kHz2_FREQ: NE? 1.109 Hz/K?
PAY_15kHz3_FREQ: WE 1.720 Hz/K
PAY_15kHz4_FREQ: WI? 1.357 Hz/K?
PAY_15kHz5_FREQ: unclear

[Modes around 26.2kHz (time series plot, temperature vs line frequency plot, B1 spectrum)]
PAY_26kHz1_FREQ: WE? 2.033 Hz/K
PAY_26kHz2_FREQ: unclear
PAY_26kHz3_FREQ: WE? 2.021 Hz/K

[Modes around 9.67-8kHz (time series plot 1-4 5-8, temperature vs line frequency plot 1-4 5-8, B1 spectrum)]
PAY_9pt6kHz1_FREQ: WI 0.849 Hz/K
PAY_9pt6kHz2_FREQ: NI 0.840 Hz/K
PAY_9pt6kHz3_FREQ: WI (noisy)
PAY_9pt6kHz4_FREQ: NI (noisy)
PAY_9pt6kHz5_FREQ: NE 0.629 Hz/K? (line moves to 9pt6kHz6)
PAY_9pt6kHz6_FREQ: lower frequency from NE 0.778 Hz/K?, upper frequency from WE 0.831 Hz/K
PAY_9pt6kHz7_FREQ: NE, but basically no line in the band (line moves to 9pt6kHz8)
PAY_9pt6kHz8_FREQ: lower frequency from NE, upper frequency from WE (noisy)

[Modes around 39.2-3kHz (time series plot 1-4 5-8, temperature vs line frequency plot 1-4 5-8, B1 spectrum)]
PAY_39kHz1_FREQ: unclear
PAY_39kHz2_FREQ: unclear
PAY_39kHz3_FREQ: WE 3.635 Hz/K?
PAY_39kHz4_FREQ: unclear
PAY_39kHz5_FREQ: currently no line in the band
PAY_39kHz6_FREQ: WI 3.208 Hz/K
PAY_39kHz7_FREQ: WE 3.291 Hz/K
PAY_39kHz8_FREQ: WI? 3.742 Hz/K

[Modes around 43.9-44.1kHz (time series plot, temperature vs line frequency plot, B1 spectrum)]
PAY_44kHz1_FREQ: unclear
PAY_44kHz2_FREQ: unclear
PAY_44kHz3_FREQ: WI? 3.633 Hz/K?
PAY_44kHz4_FREQ: unclear
PAY_44kHz5_FREQ: currently no line in the band
PAY_44kHz6_FREQ: unclear

Dots in different colors indicate data from different locks.


Method:
I did a similar analysis done a year ago by Bas (logbook #39039), using 4 days of data during the commissioning run in Aug 2-5. Data in LOW_NOISE_3 is used.

1. Make temperature vs line frequency plots using ring heater temperatures (INF_TCS_NI_RH_TE, INF_TCS_WI_RH_TE, ENV_TCS_NE_RH_TE, ENV_TCS_WE_RH_TE) and line tracker frequency outputs (PAY_{mode}_FREQ).

2. Calculated correlation coefficients and linear fitted to get the temperature dependence. Used these information to identify the mirror.

3. For line tracker frequency output channels tracking two modes, I splitted the data into two using moving average using the time window of 3000 seconds. Lower frequency output is labeled with the suffix _lower, and upper frequency output is labeled with the suffix _upper.


Result:
[Drum modes around 7.807kHz]
From correlation coefficients, we can clearly see that DRUM1 is from NI and DRUM2 is from WI.
DRUM3 is now tracking nothing, and DRUM4 is tracking two modes. Lower frequency of DRUM4 can be identified to be WE from the correlation coefficient.
Upper frequency of DRUM4 is therefore NE.
These results are consistent with previous studies (logbook #41935, #41794 (this figure) and VIR-0505A-18).
The temperature dependance of drum mode frequencies is ~0.88 Hz/K, which is consistent with previous studies (logbook #39039, #41798).

[Modes around 10.107kHz]
Modes can be identified similarly with drum modes.
These results are consistent with previous studies  (logbook #41794 (this figure) and VIR-0505A-18).
The temperature dependance of mode frequencies is ~1.07 Hz/K.

[Modes around 15.007kHz]
For these modes, some of the lines moved from one channel to different channel, so I only used the first half (~ 2 days) of the data.
15kHz3 can be clearly identified to be WE and is consistent with logbook #41794 (this figure).
Others are quite unclear, but considering the combination of high correlation coefficients and temperature dependance close to 1.7 Hz/K obtained from WE, 15kHz1, 15kHz2 and 15kHz4 are likely to be from NI, NE and WI respectively.

[Modes around 26.2kHz]
For these modes, the line at 26kHz2 moved out from the frequency region, so I only used the first half (~ 2 days) of the data.
Both 26kHz1 and 26kHz3 has high correlation with WE temperature, as already found in logbook #41794 (this figure).
They might not be from mirror modes, but something from WE.

[Modes around 9.6kHz]
These modes are tricky (they were also quiet during the weekend).
From study in logbook #41794 (this figure), we can see that 9pt6kHz6 and 9pt6kHz8 are from WE. There are 4 groups but they do not correspond to 4 mirrors and groups are mixed.
From correlation coefficients, we can clearly see that 9pt6kHz1 is from WI and 9pt6kHz2 is from NI.
Therefore, we can guess that 9pt6kHz3 and 9pt6kHz4 are also from WI and NI, respectively, although these channels are noisy due to small amplitude during the weekend. For fitting the data of these channels, I only used the data which has not too large fluctuation from the trend we can see by our eye (data used is indicated with black dots).
The rest is 9pt6kHz5 and 9pt6kHz7 and they are from NE. 9pt6kHz7 is currently out of band and NE mode is actually tracked by 9pt6kHz8. Also, NE line in 9pt6kHz5 moved to 9pt6kHz6 during the weekend.
We can also confirm that all the temperature dependances of mode frequencies are ~0.84 Hz/K.

[Modes around 39.2-3kHz]
These modes were quiet and unclear.
From study in logbook #41794 (this figure and this figure), we can see that 39kHz3 and 39kHz7 are from WE, and correlation coefficients support this.
We can also see that 39kHz6 and 39kHz8 have high coherence with WI temperature and similar temperature dependance (~3.2-3.7 Hz/K).
For 39kHz1, it was noisy and unclear.
For 29kHz2, correlation coefficients are similar for each mirror and unclear.
For 39kHz4, the line moved away from the band and we don't have much data.
If you look at the B1 spectrum, we see peak at 39306 Hz, which is not tracked by the line tracker. No line in 39kHz5 band.
We might have to check these modes and line tracker bands again when these modes are excited.

[Modes around 43.9-44.1kHz]
For these modes, no plot is in logbook #41794. So, I made one here.
As you can see, no peaks in this line tracker frequency band moved during large temperature change in WE in June 10.
44kHz3 has high correlation with WI temperature, so it might be from WI, but others are unclear.
May be we should look into these modes again.