Reports 1-1 of 1 Clear search Modify search
AdV-AEI Squeezer Integration (AEI squeezer works)
carbognani - 7:43 Wednesday 14 November 2018 (43567) Print this report
Comment to SQZ alignment on OMC - 97% mode matching (43566)

> We stopped at 5:00 and tried to relock the ITF without success: north arm flashes are missing. We leave the IFT in DOWN state.

It was possible to get back the north arm flashes by having the NI and NE Automation nodes cycling to MISALIGNED -> ALIGNED in order to restore the positions recorded during the last lock period.

Locking attempts ongoing.