This morning the residual offsets on the SDB2 quadrants DC channels were checked:
B5_QD1 H -4.27046e-05 V 4.80133e-05 Sum -3.26598e-04
B5_QD2 H -1.64740e-04 V 1.71002e-04 Sum -7.35306e-06
B1p_QD1 H -1.77353e-02 V 7.63090e-06 Sum 7.06499e-05
B1p_QD2 H 4.57601e-05 V 7.29158e-05 Sum 6.02074e-05
We tried to correct all offsets exceeding 1.0e-4. This was successful on B5. On B1p_QD1 the Horizontal channel still has a residual offset of 6.1e-04 which cannot be corrected due to the large offset fluctuations on this channel.