The EQB1_DBOX_03 was found in timing_errorc since 06h48m_UTC (see the attached plot), usually this occurred dutrng each maintenance period .
The recovery was performed between 2026-10-09-10h41m16-UTC and 2026-10-09-10h43m45-UTC.
Below the details of the procedure to perform to recover the correct running confitions
Fom this VirgoOnline VPM window
- remove the SQ1_dbox_rack server from the FbsDet server
- stop the EQB1_HD_CC server
- from the SQB1_dbox_rack server
- re-configure the full EQB1_DBOX_03 dbox board
- in the DMS interface, the Daq_EER_DBOX3_timing_error flag shoud be green but the EQB1_HD_CC_DAC_ssfs_flags and the SQZ_CC_DAC_ssfs_flags are red now
- then re-configure the EQB1_HD_CC_DAC FAST_DAC mezzanine
- re-configure the full EQB1_DBOX_03 dbox board
- restart the EQB1_HD_CC server
- in the DMS interface, the EQB1_HD_CC_DAC_ssfs_flags shoud be green
As there is some signals from the EQB1_DEMOD_03 demodulation mezzanine sent the SQZ coherent control FAST_DAC mezzanine, this one has to be re-synchronized.
From this VirgoOnline VPM window
- stop the SQZ_CC_Ctrl server
- from the SQZ_DBOX_DET_EERoom server
- re-configure the SQZ_CC_DAC FAST_DAC mezzanine
- restart the SQZ_CC_Ctrl server
- in the DMS interface, the SQZ_CC_DAC_ssfs_flags shoud be green
- perform the reloadConfig of FbsDet server to restore the SMS data collection of the SQB1_dbox_rack server