06:00 UTC ITF found with the following loops open:
- top stage IB, OB, PR, SR, BS, NI, WI
- F7 BS, WI
- LC BS
- Position and angular SPRB, SDB2, SNEB, SEWB
ITF was put in DOWN with ITF_LOCK and INJ_MAIN nodes in pause.
I was able to close some of them but SIB1 and WI had too high a correction to hold. Manuel started working on the issue while I called Valerio (work in progress), since we noticed that many stages of different suspensions were close to saturation and needed to be moved with motors.
SBEs closed.
08:15 UTC I changed the TCS Aux cooling chiller setpoint from 17 to 16.1. Heating loop setpoints: WI 17.4, NI 17.2. CO2 CH powers are back to before adding glycol.
10:00 UTC ALS NE malfunction assessment: L1 power supply not working (Cavalieri, Spinicelli)
12:00 UTC ITF in LOCKED_ARMS_IR