Reports 1-1 of 1 Clear search Modify search
AdV-DET (Commissioning)
masserot - 22:18 Sunday 30 August 2026 (69669) Print this report
SDB2 bench : SDB2_DBOX_LeftUp found down

As already experimented  2 times during the week from 17-22 August, the  SDB2_DBOX_LeftUp DBox was found unreachable in the Tolm network since 2026-08-30-14h22m05

 Its have been recovered by performing 

  • an OFF/ON using  the  SDB2_POWERSUPPLY  server 
  • and a full reconfiguration of  the SDB2 bench DBoxes 
  • Operations performed betxeeen 2026-08-30-18h32m45-UTC and  2026-08-30-18h57m14-UTC

The problem is not understood. For the time being

  • all the SDB2 suspension controls have been left open
  • the ITF_LOCK Metatron node put in DOWN

The attached plot shows  the trend of the DBOXes' timing error channels and their  12V power supply channels before the event, during the event, and after the DBoxes reconfiguration

Images attached to this report
Comments to this report:
mwas - 22:00 Sunday 30 August 2026 (69670) Print this report

DET_MAIN was stuck in UNKNOWN state because of a large offset on B1 PD3. After adjusting the offset around 19:45 UTC, I could put back DET_MAIN into the SHUTTER_CLOSED state. And then lock the arms using ITF_LOCK. SDB2 is not used for locked arms, so it should be ok to keep the arms locked even if SDB2 is not controlled.

gouaty masserot - 10:34 Monday 31 August 2026 (69671) Print this report

The same plot related to 2 events that occurred on 2026-08-20-04h58m40-UTC and on  2026-08-20-08h51m30-UTC :

  • For each of these events, the timing_error signal of the RightUp and RightDown DBoxes were still correctly collected 
Images attached to this comment