DAQ maintenance

There was the following DBoxes with the timing_error not at zero , this appeared around 08h50m-UTC for most of them:

  • EDB_DBOX_OMC (SN075) and EDB_DBOX_SQZ(SN120) managed by the EDB_QD_dbox_rack server
    • Related to EDB_DBOX_SQZ(SN120), the demodulation board SN38 (mezzanine3) appeared as not available for the DaqBox server, but was weel reachable from the DBox ARM CPU
      • from the DBox ARM CPU; the command /home/daqbox/virgo/App/DaqBox/v8r3/scripts/daqbox_main_fpga_reset.sh  was executed and after the the faultymezzanine was recovered
    • The reconfiguration of these DBoxes allowed to recover the synchronization with the Timing system
  • SQB1_DBOX_Up (SN103) and SQB1_DBOX_Up(SN104)  managed by the SQB1_dbox_bench server
    • the LC and SBE SQB1 controls were openned 
    • The reconfiguration of these DBoxes alloweed to recover the synchronization with the Timing system
    • the LC and SBE SQB1 controls were successfully closed after these operations
  • EQB1_DBOX_03 (SN091) managed by the SQB1_dbox_rack server and the SQZ_DBOX_O2 managed by the  SQZ_DBOX_DET_EERoom server
    • The reconfiguration of these DBoxes allowed to recover the synchronization with the Timing system

After these operations, all the faulty DBOxes are synchronized  as well the FAST_DAC mezzanines . The attached plot show the trend of the issues 